K223 / K224 / 2027
Practical electricity overview

Full chapter

Practical electricity

All 8 topics and the revision summary on one page.

01

Electrical heating and power

Make a guess. You are not marked.

A kettle's heating element and the cable joined to it carry the same current. Which gets much hotter?

  1. The cable, because the current reaches it first.
  2. The element, because almost all of the 230 V is across it.
  3. Both get equally hot, because the current is the same.
Show the answer

The element, because almost all of the 230 V is across it.

The same current flows through both, and power is P = VI. The element has a high resistance, so nearly all of the p.d. is across it. The cable has a tiny p.d. across it, so it transfers very little energy.

In short

  • A heating element has a high resistance. A current in it transfers energy, so it gets hot.
  • Power is how fast energy is transferred. 1 W is 1 J every second.
  • P = VI. Use the p.d. across the part and the current through it.
  • E = Pt = VIt. Use t in seconds to get E in joules.

A heating element turns electrical energy into heating. Its power, P = VI, tells you how much energy it transfers each second.

Current is the charge passing a point each second. Potential difference (p.d.) is the energy transferred per coulomb. Power is energy transferred per second: 1 watt (W) is 1 joule per second.

How a heating element works

A heating element is a coil or strip of wire with a high resistance. As charge flows through it, the charge transfers energy to the wire. The wire's internal energy rises, so it gets hot. The hot element then heats whatever is around it.

Electric kettle
The element sits in the water. It heats the water touching it, and convection carries the heat through the rest of the water.
Electric oven
The elements heat the air inside the oven. The hot air and the infrared radiation from the elements cook the food.
Electric heater
The hot element heats the air around it. The warm air rises and spreads through the room by convection. A glowing element also gives out infrared radiation.

Kettles were not always built this way. In 1922, Leslie Large, an engineer at Bulpitt & Sons in Birmingham, sealed a kettle element inside a metal tube. It could sit right in the water, so it wasted far less energy than a kettle heated on a stove.

Power: P = VI

Each coulomb that passes through the element transfers V joules, where V is the p.d. across it. A current I means that I coulombs pass each second. So the energy transferred each second is V x I.

P = VI    E = Pt = VItUnits: P in watts (W), V in volts (V) and I in amperes (A). Use t in seconds (s) to get E in joules (J).

Use the p.d. across a part and the current through that same part. Change minutes to seconds before you find the energy in joules.

Power, then energy

A heater running for 12 minutes

A heater runs at 230 V and takes a steady 5.0 A for 12 minutes.

P = VI = 230 x 5.0 = 1150 W, which is 1.15 kW.

t = 12 x 60 = 720 s, so E = Pt = 1150 x 720 = 828 000 J.

Try it step by step

Work it out in steps: Power P = VI in W, then Time in s, then Energy E = Pt in J.

  1. Problem 1. A kettle element runs at 230 V and 2.0 A for 5.0 minutes. Find its power and the energy it transfers.
  2. Problem 2. A 12 V car fan draws 3.0 A for 10 minutes. Find its power and the energy it transfers.
  3. Problem 3. A heater runs at 230 V and 4.0 A for 15 minutes. Find its power and the energy it transfers.
Show the answer

Problem 1.

Power P = VI in W: P = VI = 230 x 2.0 = 460 W

Time in s: t = 5.0 x 60 = 300 s

Energy E = Pt in J: E = Pt = 460 x 300 = 138000 J, which is 138 kJ (3 sf)

Problem 2.

Power P = VI in W: P = 12 x 3.0 = 36 W

Time in s: t = 10 x 60 = 600 s

Energy E = Pt in J: E = 36 x 600 = 21600 J, which is 21.6 kJ (3 sf)

Problem 3.

Power P = VI in W: P = 230 x 4.0 = 920 W

Time in s: t = 15 x 60 = 900 s

Energy E = Pt in J: E = 920 x 900 = 828000 J, which is 828 kJ (3 sf)

More detail (optional)

These formulas give the electrical energy put in. Not all of it heats the water or the food. Some of it heats the kettle itself and the air around it.

The current is not used up. The same current flows into the element and out of it. The element takes energy from the charge, not the charge itself.

Check your understanding

A heater element takes a current of 5.0 A from the live wire. What is the current in the neutral wire that leaves the element?

  1. Less than 5.0 A, because the element uses up some of the current to make heat.
  2. Zero, because the current is turned into heat in the element.
  3. 5.0 A, because the charge is not used up.
Show the answer

5.0 A, because the charge is not used up.

Charge flows into the element and out again. The element takes energy from the charge, not the charge itself, so the current out equals the current in.

02

Measuring electrical power

Make a guess. You are not marked.

A lamp is in series with a resistor across a supply. To find the lamp's power, a student puts the voltmeter across the supply instead of across the lamp. Is her answer for the power too big, too small or right?

  1. Right, because the current is the same everywhere in a series circuit.
  2. Too small, because some energy is lost in the wires.
  3. Too big, because the supply p.d. is larger than the lamp's p.d.
Show the answer

Too big, because the supply p.d. is larger than the lamp's p.d.

The supply p.d. is shared between the lamp and the resistor. Using the whole supply p.d. with the lamp's current gives the power of both parts together, which is more than the lamp's power.

In short

  • Put an ammeter in series with the part to measure the current through it.
  • Put a voltmeter across the same part to measure the p.d.
  • Multiply the two readings: P = VI. Then E = Pt.

To find the power of a part, measure the current through it and the p.d. across it at the same time. Then multiply them: P = VI.

An ammeter goes in series with the part. A voltmeter goes across it, in parallel. Energy is power x time: E = Pt.

Measure the p.d. across the part and the current through it

The ammeter A is in series with the part. The voltmeter V is joined across the part's two ends, P and Q.

Measuring the current through a part and the p.d. across itA low-voltage d.c. supply is on the left. Ammeter A is in the top wire, in series with a part joined between P and Q. The voltmeter is joined across P and Q. The ammeter reads 0.40 A and the voltmeter reads 6.0 V. The switch at the bottom is closed.+-D.c. sourceA+-0.40 AComponentPQV+-6.0 V across P/QSwitch closed

The voltmeter takes almost no current, so the ammeter reading is the current through the part.

The readings stay at 6.0 V and 0.40 A for 180 s.

For this part, P = VI = 6.0 x 0.40 = 2.4 W. In 180 s it transfers E = Pt = 2.4 x 180 = 432 J.

Taking the readings

  1. Use a low-voltage supply, never the mains.
  2. Join the ammeter in series with the part, and the voltmeter across it.
  3. Choose meter ranges that the readings will fit. Write down each reading with its unit.
  4. Time how long the current flows. Check the readings now and then, because a part that warms up can change its current.
  5. Work out P = VI from readings taken at the same time. Then find E = Pt.

James Joule measured the heating from a current in this way. In 1840 he published his finding that a current can heat a wire. He put a wire in water, passed a known current through it for 30 minutes and measured how much the water warmed.

More detail (optional)

If the current changes as the part warms up, use the average power over the time in E = Pt. If the p.d. stays fixed, you can use the average current in E = VIt.

Power is V x I, not V / I. 6.0 / 0.40 = 15 is the resistance in ohms, not the power in watts.

Check your understanding

A low-voltage component has a steady 6.0 V across it and 0.40 A through it for 180 s. Which result describes its electrical input?

  1. Power is 2.4 W and input energy is 2.4 J.
  2. Power is 2.4 W and input energy is 432 J.
  3. Power is 15 W and useful output energy is 2700 J.
Show the answer

Power is 2.4 W and input energy is 432 J.

P = VI = 6.0 x 0.40 = 2.4 W. E = Pt = 2.4 x 180 = 432 J. These readings describe electrical input; they do not determine how much becomes a particular useful output.

03

Energy use and cost

Make a guess. You are not marked.

A 2.0 kW kettle is used for 15 minutes. A 0.50 kW rice cooker is used for 1 hour. Which uses more energy?

  1. Neither: each uses 0.50 kW h.
  2. The kettle, because its power is four times bigger.
  3. The rice cooker, because it runs four times longer.
Show the answer

Neither: each uses 0.50 kW h.

Kettle: 2.0 kW x 0.25 h = 0.50 kW h. Rice cooker: 0.50 kW x 1.0 h = 0.50 kW h. Energy depends on power and time together.

In short

  • The electricity bill counts energy in kilowatt-hours, kW h.
  • 1 kW h is the energy a 1 kW appliance uses in 1 hour.
  • Energy in kW h = power in kW x time in hours.
  • Cost = energy in kW h x price per kW h.

You pay for the energy you use, not for the power. Find the energy in kilowatt-hours, then multiply by the price per kilowatt-hour.

Energy = power x time, or E = Pt. A more powerful appliance uses energy faster, but the total also depends on how long it runs.

The kilowatt-hour

A kilowatt-hour (kW h) is the energy a 1 kW appliance transfers in 1 hour. It is a unit of energy, like the joule, but much bigger.

1 kW h = 1000 W x 3600 s = 3 600 000 JUse kW and hours to get kW h. Use W and seconds to get J.

A kilowatt (kW) is a unit of power. A kilowatt-hour is a unit of energy: power multiplied by time. Do not write kW/h, which means something else.

In Singapore, the Energy Market Authority regulates the price of electricity for homes and revises it every three months. For October to December 2026, SP Group's price was 31.16 cents per kW h, including GST. Exam questions tell you the price to use.

Use hours with kilowatts

The cost of the 12-minute heater

The heater from the power lesson uses 1.15 kW for 12 minutes. First, t = 12/60 = 0.20 h.

Energy = 1.15 x 0.20 = 0.230 kW h. As a check, 0.230 x 3 600 000 = 828 000 J, the same as before.

At a price of $0.30 per kW h, cost = 0.230 x $0.30 = $0.069, or 6.9 cents. To the nearest cent, that is $0.07.

Try it step by step

Work it out in steps: Power in kW, then Energy in kW h, then Cost in cents.

  1. Problem 1. A 2000 W heater runs for 3.0 hours. Electricity costs 30 cents per kW h. Find the cost.
  2. Problem 2. A 1500 W air conditioner runs for 2.0 hours. Electricity costs 30 cents per kW h. Find the cost.
  3. Problem 3. An 800 W rice cooker runs for 5.0 hours in a week. Electricity costs 30 cents per kW h. Find the cost for the week.
Show the answer

Problem 1.

Power in kW: P = 2000 / 1000 = 2.0 kW

Energy in kW h: E = 2.0 x 3.0 = 6.0 kW h

Cost in cents: Cost = 6.0 x 30 = 180 cents, which is $1.80

Problem 2.

Power in kW: P = 1500 / 1000 = 1.5 kW

Energy in kW h: E = 1.5 x 2.0 = 3.0 kW h

Cost in cents: Cost = 3.0 x 30 = 90 cents

Problem 3.

Power in kW: P = 800 / 1000 = 0.80 kW

Energy in kW h: E = 0.80 x 5.0 = 4.0 kW h

Cost in cents: Cost = 4.0 x 30 = 120 cents, which is $1.20

Power is not the whole story

Appliance A

0.10 kW for 5.0 h

Energy = 0.10 x 5.0 = 0.50 kW h.

Appliance B

1.0 kW for 0.25 h

Energy = 1.0 x 0.25 = 0.25 kW h.

B has ten times the power of A, but it runs for a much shorter time. It uses half as much energy, so it costs half as much.

More detail (optional)

A heater with a thermostat switches itself on and off. A 1 kW heater that is on for only half of each hour uses 0.5 kW h each hour, not 1 kW h.

Change minutes to hours. 12 minutes is 12/60 = 0.20 h. It is not 12 h, and it is not 0.12 h.

Check your understanding

A heater uses a constant 1.15 kW for 12 minutes. Using a supplied example tariff of $0.30 per kW h, what is the energy cost before rounding to the nearest cent?

  1. $4.14, or 414 cents
  2. $0.069, or 6.9 cents
  3. $0.345, or 34.5 cents
Show the answer

$0.069, or 6.9 cents

12 minutes is 0.20 h. The energy is 1.15 x 0.20 = 0.230 kW h, so cost = 0.230 x $0.30 = $0.069, or 6.9 cents.

04

Live, neutral, earth and the plug

Make a guess. You are not marked.

A plug has no cable grip, and someone pulls the appliance away by its cable. What is the danger?

  1. Nothing, because the plastic case of the plug holds the cable in place.
  2. The fuse melts at once to protect the plug.
  3. A wire can be pulled out of its terminal.
Show the answer

A wire can be pulled out of its terminal.

Without a grip, the pull goes straight to the screw terminals and can tear a wire loose. A loose live wire could touch another terminal, and a loose earth wire leaves a metal case unprotected.

In short

  • Live (brown) is at a high voltage.
  • Neutral (blue) completes the circuit. It stays close to 0 V.
  • Earth (green and yellow) is a safety wire. It carries no current unless there is a fault.
  • In the plug, brown goes to L through the fuse, blue to N and green and yellow to E.

A mains cable has three wires: live, neutral and earth. Live and neutral carry the current. Earth is there for safety.

A current needs a complete path. Mains is an alternating supply: the current keeps changing direction.

The three wires

Live (L): brown
Live is at a high voltage compared with earth. In Singapore the mains supply is 230 V. Touching live can give a fatal shock.
Neutral (N): blue
Neutral completes the circuit back to the supply. It is kept close to 0 V. In a working appliance it carries the same current as live.
Earth (E): green and yellow
Earth joins a metal case to the ground. It carries no current unless there is a fault.

Inside a three-pin plug

Inside a three-pin plug

The back cover is off and the cable enters at the bottom. Looking at the pins from the front would swap left and right.

Live, neutral, earth, fuse and cable grip inside a three-pin plugInside view of a three-pin plug, with the cable entering at the bottom. Earth terminal E is at the top, neutral N on the left and live L on the right. The blue wire goes to N and the green-and-yellow wire goes to E. The brown wire goes to L through the fuse. The cable grip clamps the grey outer sheath of the cable, not the separate wires.ENLFuseCable gripOutersheath
  • L: liveBrown
  • N: neutralBlue
  • E: earthGreen/yellow

The fuse is in the live wire. The cable grip takes any pull on the cable, so the wires are not pulled out of their terminals.

Brown goes to L through the fuse, blue goes to N, and green and yellow goes to E.

In a correctly wired plug, the brown wire goes to the live pin through the fuse. The blue wire goes to neutral, and the green-and-yellow wire goes to earth.

The cable grip clamps the cable's outer sheath. If someone pulls the cable, the grip takes the pull instead of the screw terminals. Each wire also has its own insulation, which keeps the wires apart.

Singapore uses the British-style three-pin plug, called BS 1363 or Type G. Its earth pin is longer than the other two. So the earth connects first when you push the plug in, and it disconnects last.

Earth is not the return wire. In a working appliance, current flows out along live and back along neutral. The earth wire carries current only when there is a fault.

Check your understanding

A kettle with a metal case is working normally. Which of these describes the currents in its three wires?

  1. Live carries the current to the kettle, and earth carries it back.
  2. Live and neutral carry the same current, and earth carries almost none.
  3. The three wires share the current equally.
Show the answer

Live and neutral carry the same current, and earth carries almost none.

The working circuit is live, element and neutral. The earth wire joins the metal case to the ground and carries current only if there is a fault.

05

Why switches and fuses go in the live wire

Make a guess. You are not marked.

A heater is wired with its switch in the neutral wire instead of the live wire. The switch is turned off and the heater stops. Is it safe to touch the heating element?

  1. It is safe as long as the plug is earthed.
  2. Yes. The heater is off, so no current can flow.
  3. No. The element is still connected to live.
Show the answer

No. The element is still connected to live.

Switching the neutral only breaks the return path. The element stays joined to the live wire, so a person touching it can complete a path to earth and get a shock.

In short

  • Switches, fuses and circuit breakers must be in the live wire.
  • Then, when they open, the appliance is cut off from the high voltage.
  • A switch in neutral turns the appliance off but leaves it joined to live. That is dangerous.

A switch, fuse or circuit breaker must be in the live wire. Then, when it opens, it cuts the appliance off from the high voltage.

Live is at a high voltage and neutral is close to 0 V. A switch breaks a circuit by opening a gap in one wire.

Off does not always mean safe

Both circuits have the same a.c. supply and load. Amber shading marks every part still joined to live. It is not a current arrow.

Switch in the live wire

Switch in the live wireAn a.c. supply is on the left, with live at the top and neutral at the bottom. The switch in the live wire is open, so no current flows. Only the live wire on the supply side of the gap is shaded amber. The load is no longer joined to live.LoadA.c.LiveNeutralOpenI = 0

The gap cuts the load off from live. The load is joined only to neutral, which is close to 0 V.

Switch in the neutral wire

Switch in the neutral wireThe same supply and load, but now the open switch is in the neutral wire. The live wire to the load is unbroken. No current flows, so there is no p.d. across the load. The amber shading covers the live wire, the load and the blue wire up to the gap. All of these are still at the live voltage, although the appliance is off.LoadA.c.LiveNeutralOpenI = 0

No current flows, but the load and the blue wire up to the gap are still joined to live. Turning the appliance off has not made it safe.

Both switches stop the current. Only the switch in live cuts the appliance off from live.

A switch in the live wire

When this switch opens, the path from the live supply to the appliance is cut. The appliance is now joined only to neutral, which is close to 0 V. No part of it is at the high voltage.

A switch in the neutral wire

Opening a switch in neutral still stops the current, so the appliance turns off. But the appliance is still joined to live. With no current, there is no p.d. across the element, so all of it is at the live voltage.

Someone who touches it could become a path to earth and get a shock. The danger is easy to miss, because the appliance looks switched off.

Fuses and circuit breakers too

A fuse or circuit breaker cuts the current when there is a fault. It must be in live for the same reason. If a fuse in neutral melted, the appliance would stop working, but it would still be joined to live.

A BS 1363 plug fits a socket only one way round. So its fuse is always on the live side.

Switches around a home

In a home, the lamps and sockets are joined in parallel across live and neutral. Each one gets the full 230 V and can be switched on and off by itself. Singapore homes have separate lighting circuits and socket circuits.

Off does not always mean safe. A switch in the neutral wire stops the current but leaves the appliance at the live voltage.

Check your understanding

In a simple mains appliance circuit, a single-pole switch opens only the neutral wire. The appliance stops operating. Which of these explanations is correct?

  1. Stopping the current makes every part of the appliance have zero potential relative to earth.
  2. The normal current path is broken, but parts of the appliance can remain connected to live.
  3. The protective earth becomes the normal return wire.
Show the answer

The normal current path is broken, but parts of the appliance can remain connected to live.

Opening neutral stops the normal load current, but it does not disconnect the live connection. A single-pole switch belongs in live so that opening it disconnects the appliance from live supply.

06

Dangers of electricity

Make a guess. You are not marked.

A person touches the same faulty live part twice: once with dry hands and once with wet hands. When is the current through the person larger?

  1. The same both times, because the voltage is the same.
  2. With wet hands, because wet skin has a much lower resistance.
  3. With dry hands, because dry skin builds up more charge.
Show the answer

With wet hands, because wet skin has a much lower resistance.

The voltage is the same both times. Wet skin has a much lower resistance, so the current I = V/R is larger and the shock is worse.

In short

  • Damaged insulation can leave a live wire bare. Touching it can give a shock.
  • Too much current overheats a cable. Its insulation can melt or catch fire.
  • Water lowers the resistance of skin and can conduct. In damp places a shock is worse.

Electricity is dangerous when current flows where it should not: through a person, or through a cable too thin for it.

For a fixed p.d., a smaller resistance gives a larger current. Any current heats the wire it flows through.

Damaged insulation

Insulation is the plastic covering around each wire. If it is cracked or worn, the live wire inside may be bare. A person who touches it can get an electric shock, as current flows through their body to earth. A bare live wire can also touch a metal case and make the case live.

Overheating cables

Every cable has some resistance, so a current heats it. Each cable is made for a certain largest current. Too much current, for example from too many appliances on one adaptor, makes it too hot. Its insulation can then melt and a fire can start.

In Singapore, the SCDF recorded 304 home fires of electrical origin in 2025. It said most were caused by faults in wiring or appliances, or by overloaded sockets.

A cable that cannot lose heat overheats sooner. A cable reel used while still wound up is one example. Electrical Safety First, a UK safety charity, says its safe current can then fall to 3 or 4 A.

Damp conditions

Tap water has salts dissolved in it, so it conducts. Wet skin also has a much lower resistance than dry skin. For the same voltage, a lower resistance means a larger current through the body. So a shock in a bathroom, or with wet hands, is more dangerous.

Say what each hazard leads to. "Water conducts" is not enough. Add that a larger current can flow through the person and give a severe shock.

Check your understanding

A kettle, an iron and a heater are all plugged into one adaptor in a single socket and switched on. Why is this dangerous?

  1. The currents add up and can overheat the shared cable, starting a fire.
  2. Each appliance gets a higher voltage, so it can burn out.
  3. The current is shared out, so each appliance gets too little to work safely.
Show the answer

The currents add up and can overheat the shared cable, starting a fire.

The appliances are in parallel, so each takes its own current. All of these currents flow through the shared socket and cable, and a current far above their rating heats them until the insulation can melt or burn.

07

Fuses and circuit breakers

Make a guess. You are not marked.

A circuit breaker trips when a faulty heater is switched on. Someone resets it at once without fixing the heater. What happens?

  1. It trips again, because the fault still draws too large a current.
  2. The heater now works, because resetting fixes the fault.
  3. The breaker stays closed, because it adjusts its rating to suit the heater.
Show the answer

It trips again, because the fault still draws too large a current.

Resetting closes the switch, but the fault is still there. The large current flows again, so the breaker opens again. The fault must be fixed first.

In short

  • A fuse is a thin wire that melts if the current gets too large. This breaks the circuit.
  • Choose the smallest fuse rating above the appliance's normal current.
  • A circuit breaker does the same job, but you can reset it.
  • Both go in the live wire.

A fuse or circuit breaker cuts off the current when it gets too large. This stops cables from overheating and starting a fire.

Too much current can make a cable overheat. Protection must be in the live wire.

The fuse

A fuse contains a short, thin wire. If the current gets too large, the wire gets hot enough to melt. This breaks the circuit and stops the current. A melted fuse must be replaced, once the fault is fixed.

A fuse has a rating in amperes. This is the largest current it carries without melting. It does not melt the instant the current passes the rating; a larger current melts it faster.

Choosing the rating

Choose the smallest rating that is above the appliance's normal current. Then the fuse carries the normal current, but it melts soon in a fault.

Find the normal current first

A 460 W appliance at 230 V

The fuses on offer are 3 A and 13 A.

Normal current I = P/V = 460/230 = 2.0 A.

Choose 3 A, the smallest rating above 2.0 A. A 13 A fuse would let the current rise to more than six times its normal value before melting.

Fuses come in standard ratings. BS 1363 plugs, the type used in Singapore, take fuses made to the British standard BS 1362. Its preferred plug fuses are 3 A, coloured red, and 13 A, coloured brown.

Try it step by step

Work it out in steps: Normal current I = P / V in A, then Fuse rating to choose.

  1. Problem 1. A 1150 W heater runs at 230 V. Fuses of 3 A, 5 A and 13 A are available. Which fuse should be fitted?
  2. Problem 2. A 920 W iron runs at 230 V. Fuses of 3 A, 5 A and 13 A are available. Which fuse should be fitted?
  3. Problem 3. A 460 W television runs at 230 V. Fuses of 3 A, 5 A and 13 A are available. Which fuse should be fitted?
Show the answer

Problem 1.

Normal current I = P / V in A: I = P / V = 1150 / 230 = 5.0 A

Fuse rating to choose: A 5 A fuse is not above the 5.0 A normal current, so it leaves no margin, and 3 A is too small. So the 13 A fuse is fitted: the smallest rating above the normal current.

Problem 2.

Normal current I = P / V in A: I = 920 / 230 = 4.0 A

Fuse rating to choose: The 5 A fuse is the smallest rating above 4.0 A, so it carries the normal current and blows soonest in a fault.

Problem 3.

Normal current I = P / V in A: I = 460 / 230 = 2.0 A

Fuse rating to choose: The 3 A fuse is the smallest rating above 2.0 A.

The circuit breaker

A circuit breaker is a switch that opens by itself when the current is too large. Once the fault is fixed, you reset it with its switch; nothing needs replacing. In a home, each circuit has its own circuit breaker in the distribution board.

More detail (optional)

A residual current circuit breaker (RCCB) works differently. It compares the current in live with the current in neutral. If some current leaks away, for example through a person, it cuts the supply. A home RCCB in Singapore trips when about 30 mA leaks away.

Work from the appliance's own current. Do not use the socket's 13 A or the main circuit's rating. A fuse far above the normal current lets a fault go on for longer before it melts.

Check your understanding

A supplied model appliance takes 460 W at 230 V, with negligible starting surge and a suitable cord. Its permitted fuse options are 3 A and 13 A. Which choice follows from these conditions?

  1. 3 A: it carries the 2.0 A normal current and blows sooner if a fault occurs.
  2. Neither, because the fuse rating must equal 230 V.
  3. 13 A, because a larger rating gives better protection and blows less often in normal use.
Show the answer

3 A: it carries the 2.0 A normal current and blows sooner if a fault occurs.

I = P/V = 460/230 = 2.0 A. Under the stated no-surge and suitable-cord conditions, 3 A is the lower permitted rating above the operating current. Real equipment needs its specified fuse.

08

Earthing and double insulation

Make a guess. You are not marked.

A hair dryer has a plastic case and a cable with only two wires, live and neutral. Is it unsafe because it has no earth wire?

  1. No, because the fuse protects the user from any shock.
  2. Yes, because every appliance needs an earth wire to be safe.
  3. No, if it is double insulated.
Show the answer

No, if it is double insulated.

A double-insulated appliance has two separate layers of insulation between the live parts and anything you can touch. Live cannot reach the outside, so it needs no earth wire.

In short

  • The earth wire joins a metal case to the ground.
  • If live touches the case, a large current flows through the earth wire and the fuse melts.
  • A double-insulated appliance has two layers of insulation and needs no earth wire.

A metal case must be earthed. If a live wire touches it, the earth wire carries a large current that melts the fuse and cuts off the live supply.

The fuse is in the live wire. For a fixed p.d., a low resistance gives a large current.

Why a metal case needs an earth wire

Metal conducts. If a loose live wire touches the metal case of an appliance, the whole case becomes live. Without an earth wire, it stays at the live voltage. Anyone who touches it gets a shock, as current flows through them to the ground.

How the earth wire makes the fuse melt

The neutral and earth wires are separate in the appliance. They are joined only at the supply. The arrows show one instant, because a.c. keeps reversing.

Normal use: current in live and neutral

Normal use: current in live and neutralAn a.c. supply is on the left. The live wire runs through a fuse to terminal L_a of a load inside a metal case. Terminal N_a returns along the blue neutral wire to the supply. A green-and-yellow earth wire joins the metal case to the supply's earth connection. Purple arrows show the normal current at one instant: live, fuse, load, neutral and back to the supply. No current flows in the earth wire.A.c.sourceFuseSupply LLoadL_aN_aMetalcaseSupply N /earth bondProtective earth (PE)

Purple arrows: the normal current

The working circuit is live, load and neutral. The earth wire is joined to the case but carries no current.

Fault: live touches the case

Fault: live touches the caseThe same circuit, but now the live terminal L_a touches the right wall of the metal case. The fuse has not melted yet. Orange arrows show a new path at one instant: live, fuse, the fault, the metal case, the earth wire and back to the supply. The arrows show the path, not the size of the current. The earth path has a very low resistance, so the current is large enough to melt the fuse.A.c.sourceFuseSupply LLoadL_aN_aMetalcaseSupply N /earth bondProtective earth (PE)Fault

Orange arrows: the fault current

The fault makes a new path through the case and the earth wire. Its resistance is very low, so a large current flows and the fuse in live melts.

The small pale blocks are insulators where the wires pass through the case.

On the left the appliance works normally. On the right a fault joins live to the case.

How the earth wire protects you

  1. Live touches the metal case.
  2. The earth wire gives the current a path of very low resistance from the case back to the supply.
  3. So a very large current flows from live, through the case and the earth wire.
  4. This current is far above the fuse rating, so the fuse in the live wire melts.
  5. The appliance is cut off from live. The case is no longer at a high voltage, so it is safe to touch.

Double insulation

Two layers between live parts and you

A cut-away view of two layers of insulation. The square inside a square marks a double-insulated appliance.

Double insulation and its symbolAt the top is the double-insulation symbol: a small square inside a larger square. Below, the live parts in the middle are wrapped in insulation layer 1, and then in a separate insulation layer 2. The outer surface, which a person can touch, has no earth wire.Double-insulation symbolLive parts12Accessible outer surface
  1. Basic insulation covers the live parts.
  2. Extra insulation is a separate second layer between them and the outside.
If one layer fails, the other still keeps live away from you.

Some appliances have a plastic case and are double insulated. Two separate layers of insulation keep the live parts away from anything you can touch. They need no earth wire, so their cable has only live and neutral.

A double-insulated appliance is labelled with the words "double insulated" or with its symbol, a square inside a square. Phone chargers are usually built this way.

More detail (optional)

A plastic case alone does not make an appliance double insulated. Look for the square-inside-a-square mark.

The earth wire does not make the case safe on its own. It carries the large current that melts the fuse. Mention both the earth wire and the fuse in the live wire.

Check your understanding

A live wire contacts an earthed metal casing. In the stated fault model, the protective earth gives a low-resistance return to the supply and the live-wire overcurrent protection is suitable. How does this arrangement protect?

  1. A large fault current flows through a complete return path, allowing the protection to interrupt live.
  2. Earth normally carries the load current, so it stops any current from entering the live wire.
  3. The fault current leaves the casing and spreads into the ground without needing a return path.
Show the answer

A large fault current flows through a complete return path, allowing the protection to interrupt live.

The low-resistance protective path keeps the casing closer to earth potential and allows sufficient fault current for the appropriate fuse or breaker to open live. The path and device must both be suitable; earth is not the normal load return.

Revision summary

Heating and power

Kettles, ovens and heaters use the heating effect of a current in a high-resistance element. The charge transfers energy to the element, which heats the water, food or air. The current is not used up.

Power: P = VI
P in watts (1 W = 1 J/s). V is the p.d. across the part and I the current through it.
Energy: E = Pt = VIt
t in seconds gives E in joules.
Units
1 kW = 1000 W; 1 min = 60 s; 1 h = 3600 s.

Measuring power

Put an ammeter in series with the part and a voltmeter across it. Use a low-voltage supply, read both meters at the same time and time the current. P = V x I, not V / I.

Kilowatt-hours and cost

Energy in kW h = power in kW x time in h. 1 kW h = 3 600 000 J. Cost = energy in kW h x price per kW h. For example, 1.15 kW for 0.20 h is 0.230 kW h, which costs 6.9 cents at $0.30 per kW h.

The three wires and the plug

  • Live: brown, at a high voltage; joined to L through the fuse.
  • Neutral: blue, completes the circuit, close to 0 V.
  • Earth: green and yellow, joins a metal case to the ground; no current unless there is a fault.
  • Cable grip: clamps the outer sheath so a pull does not loosen the wires.

Switches and fuses in live

Opening a switch, fuse or circuit breaker in live cuts the appliance off from the high voltage. In neutral, it stops the current but leaves the appliance at the live voltage. Lamps and sockets in a home are in parallel, so each gets 230 V and works on its own.

Dangers of electricity

  • Damaged insulation: a bare live wire can give a shock or make a metal case live.
  • Overheating cables: too much current can melt insulation and start a fire.
  • Damp conditions: water conducts and wet skin has a low resistance, so a larger current flows through a person.

Fuses and circuit breakers

A fuse melts when the current is too large. Choose the smallest rating above the normal current, I = P/V. A circuit breaker opens by itself and can be reset after the fault is fixed.

Earthing and double insulation

If live touches an earthed metal case, a large current flows through the low-resistance earth wire. The fuse in live melts and cuts off the supply. A double-insulated appliance has two layers of insulation, needs no earth wire and is labelled as double insulated.

Back to electrical heating and power

Practise exam questions

Write your answer first, then tick the mark points it makes.

Exam-style question

A 2.0 kW heater is used for 3.0 hours each day for 30 days. Electricity costs 30 cents per kW h. Calculate the energy used in kW h and the total cost. [3]

Saved on this browser only. Anyone using this browser can see it.

Exam-style question

An electric kettle is rated 2200 W, 230 V. Fuses of 3 A, 5 A and 13 A are available. Calculate the normal current in the kettle and choose the most suitable fuse. Explain why the other two are not suitable. [3]

Saved on this browser only. Anyone using this browser can see it.

Exam-style question

A washing machine has a metal case connected to the earth wire. A fault makes the live wire touch the case. Explain how the earth wire and the fuse together protect a person who then touches the case. [3]

Saved on this browser only. Anyone using this browser can see it.

Exam-style question

Data-based question: Choosing a kettle [8]

A family compares three kettles. For each one they boil 1.0 L of water, starting from tap temperature, and time how long it takes. Electricity costs $0.30 per kW h.

Table 1. Three kettles boiling 1.0 L of water
kettlepower / Wtime to boil / s
A2200150
B3000115
C1800190
  1. (a) Calculate the energy kettle A uses to boil 1.0 L of water. Give your answer in J. [2]
  2. (b) Convert your answer to (a) into kW h. [1]
  3. (c) The family boils 1.0 L five times a day. Calculate the daily cost of using kettle A. [2]
  4. (d) State one assumption you made in (c). [1]
  5. (e) A salesperson says: "Kettle B costs the most to run because it has the highest power." Use the data to evaluate this claim. [2]

Saved on this browser only. Anyone using this browser can see it.

Quick recall

Card 1 of 8. Answer in your head, then check.

A heater element takes a current of 5.0 A from the live wire. What is the current in the neutral wire that leaves the element?