Lesson 6 of 11
Standard solutions and back titration
Make a solution of known concentration and work back from a known excess.
A-Level 9476 (2026-2027)
I can explain titration and standard solutions.Syllabus
Syllabus 9476, T1. Titration and standard solutions
Prepare a known concentration and interpret indirect titrations
A standard solution has a known concentration only if all the solute reaches the flask and the solution is made up and mixed.
Make a guess. You are not marked.
A solution has been made up to the mark in a volumetric flask. Why is the flask then stoppered and inverted several times?
Show the answer
To make the solution uniform
The water added last sits near the top at first. Inverting mixes the solution, so a pipetted portion has the stated concentration.
A standard solution has a reliably known concentration. For a suitable pure, stable solid, weigh it accurately and dissolve it completely in a beaker. Transfer the solution to a volumetric flask, and wash the beaker, rod and funnel into the flask. Cool to the appropriate temperature before making up to the mark. Add the final water dropwise with the meniscus at eye level, stopper and invert repeatedly to mix. A volumetric flask contains its stated volume; it is not a device for delivering arbitrary measured portions.
Standard solutions go back to the early days of titration. In an 1824 paper on standardising indigo solutions, Joseph Louis Gay-Lussac invented the words "pipette" and "burette".
Worked examplePrepare a carbonate standard
What mass of anhydrous Na2CO3, Mr = 106.0, is needed for 250.0 cm3 of a 0.0400 mol dm-3 solution?
Try it first. Then show the worked stepsHide the worked steps
- n = cV = 0.0400 × 0.2500 = 0.0100 mol.
- m = nM = 0.0100 × 106.0 = 1.06 g. Use the actual measured mass to calculate the actual concentration.
- A 25.00 cm3 aliquot contains one tenth of the flask amount. Making a dilute solution does not change the amount transferred from the solid.
Target mass 1.06 g. Complete transfer and making to volume are both necessary.
In a back titration, first react the sample with a known excess of reagent. Measure the leftover reagent with a second titration, then subtract it from the starting amount. If only an aliquot of the leftover solution is titrated, scale that result to the whole flask before subtracting.
Worked exampleBack-titrate a carbonate sample
A 0.250 g sample is treated with 50.00 cm3 of 0.100 mol dm-3 HCl. The whole remaining acid needs 10.00 cm3 of 0.100 mol dm-3 NaOH. Only CaCO3 in the sample reacts with the acid.
Try it first. Then show the worked stepsHide the worked steps
- Starting HCl = 0.005000 mol; leftover HCl = n(NaOH) = 0.001000 mol.
- HCl consumed by sample = 0.004000 mol. CaCO3 + 2HCl -> CaCl2 + CO2 + H2O, so n(CaCO3) = 0.002000 mol.
- Using M(CaCO3) = 100.1 g mol-1, mass = 0.2002 g; percentage by mass = 0.2002 / 0.250 × 100.
80.1% CaCO3 by mass, assuming reaction is complete and other components do not consume acid.
| Method | What the signal means | Reasoning to retain |
|---|---|---|
| Acidified manganate(VII) | A faint persistent excess manganate colour marks the endpoint in the usual reduction titration | Use the specified acid and the balanced electron ratio; the titrant may be its own indicator |
| Direct iodine titration | A first persistent iodine/starch colour can mark a small excess of iodine titrant | Iodine oxidises the reducing analyte; use the stated reaction and endpoint instructions |
| Iodine-thiosulfate | Blue starch-iodine colour disappears as the final iodine is reduced | I2 + 2S2O32- -> 2I- + S4O62-; add starch near the endpoint in the usual procedure |
| Indirect iodine determination | An oxidant first liberates iodine from excess iodide | Link the oxidant:iodine ratio to iodine:thiosulfate; do not assume either stage is 1:1 |
Check your understanding
A 25.0 cm3 portion is taken from a 250.0 cm3 flask, and it contains 0.00120 mol of leftover acid. How much leftover acid is in the whole flask?
Show the answer
0.0120 mol, because the portion is one tenth of the flask
250.0 / 25.0 = 10, so multiply by ten. Use the whole-flask amount when you subtract in a back titration.
Watch out for this
A student says: "To make a standard solution, tip the weighed solid straight into the volumetric flask and add water up to the mark." What is wrong with this?
Show the answer
Dissolve the solid in a beaker first. Transfer the solution, then wash the beaker, rod and funnel into the flask, so that all the solute reaches it. A June 2022 Cambridge report names the two most common omissions. They were dissolving the solid in the beaker before transfer, and washing the beaker into the flask.