  • I can apply energy transfer = mass x specific heat capacity x temperature change.Syllabus

    Syllabus K323, 9(c). Apply energy transfer = mass x specific heat capacity x temperature change.

To measure c, supply a known amount of energy to a known mass and measure its temperature rise. Only the energy that reaches the sample counts.

E = mcΔT links the energy reaching a sample to its temperature rise. Rearranged, c = E / (mΔT).

Separate energy reaching the sample from heater input

Power is energy transferred per unit time. Suppose a 120 W heater transfers all its output to the metal sample above at a constant rate. The ideal time is t = E/P = 2700/120 = 22.5 s.

If some heater energy warms the apparatus or goes to the surroundings, less reaches the sample in that time. The same 30°C rise then needs more input energy or a longer time. The output of a heater is not always equal to the energy the sample gains.

Determine a specific heat capacity

For a suitable metal sample, use a heater of known constant power set inside the sample. Put a temperature sensor in good thermal contact with the sample. Insulation cuts the transfer to the surroundings. Keep the sample below any change of state.

  1. Measure the mass: use a balance for the sample itself, without separate supports and instruments.
  2. Measure the temperature rise: record the start and end temperatures of the sample over the chosen heating time. Place the sensor where it reads the sample, not the bare heater. Choose a suitable range and resolution, and allow for response lag.
  3. Find the supplied energy: with constant heater power P and measured time t, Einput = Pt.
  4. Use the energy account: the input warms the sample and apparatus and may escape to the surroundings. If these other transfers are small enough to ignore, or have been estimated and subtracted, c =Esample / (mΔT).

Supplied practical data

Correct the energy account

In a separate run, a 20 W heater runs for 180 s while a 0.20 kg sample warms by 30°C. A separate calibration gives two estimates. It finds that 300 J warms the apparatus and 600 J goes to the surroundings.

  1. Heater input: Einput = 20 x 180 = 3600 J.
  2. Energy reaching the sample: Esample = 3600 - 300 - 600 = 2700 J.
  3. Specific heat capacity: c = 2700 / (0.20 x 30) = 450 J/(kg °C).

Ignoring both other transfers gives 3600 / (0.20 x 30) = 600 J/(kg °C), which is too high. The correction values are given for this example. An unpowered setup stays near room temperature. So it would not by itself measure the heat loss from a sample that gets hotter as it is heated.

Try it step by step

Work it out in steps: Heater energy E = Pt in J, then Specific heat capacity c = E / (m x temperature change) in J/(kg degrees C).

  1. Problem 1. A 50 W heater runs for 120 s inside a 0.40 kg metal block, and the block warms by 30 degrees C. Assume all the heater energy reaches the block. Find the specific heat capacity of the metal.
  2. Problem 2. A 40 W heater runs for 150 s inside a 1.0 kg block, which warms by 15 degrees C. Assume all the heater energy reaches the block. Find the specific heat capacity.
  3. Problem 3. A 36 W heater runs for 250 s inside a 0.50 kg block, which warms by 20 degrees C. Assume all the heater energy reaches the block. Find the specific heat capacity.
Show the answer

Problem 1.

Heater energy E = Pt in J: E = Pt = 50 x 120 = 6000 J

Specific heat capacity c = E / (m x temperature change) in J/(kg degrees C): c = 6000 / (0.40 x 30) = 500 J/(kg degrees C) (2 sf)

Problem 2.

Heater energy E = Pt in J: E = 40 x 150 = 6000 J

Specific heat capacity c = E / (m x temperature change) in J/(kg degrees C): c = 6000 / (1.0 x 15) = 400 J/(kg degrees C) (2 sf)

Problem 3.

Heater energy E = Pt in J: E = 36 x 250 = 9000 J

Specific heat capacity c = E / (m x temperature change) in J/(kg degrees C): c = 9000 / (0.50 x 20) = 900 J/(kg degrees C) (2 sf)

If all the input is wrongly treated as energy reaching the sample, the top of the fraction is too large. The calculated c then tends to be too high. Better insulation, and allowing for the heating of the apparatus, deal with that cause. Repeating the same flawed setup may show variation but does not remove the systematic error.

Pt is the heater input, not the sample's gain. Use Pt as E only when the question says all of it reaches the sample, or after subtracting the energy that went elsewhere.

Check your understanding

A student heats a metal block with an electric heater and calculates c = Pt / (m x temperature rise). The block was not insulated. Which of these describes her value of c?

  1. Unaffected, because the power, time, mass and temperature rise were all measured correctly.
  2. Too low, because the block lost energy and warmed less.
  3. Too high, because some of the energy Pt never raised the temperature of the block.
Show the answer

Too high, because some of the energy Pt never raised the temperature of the block.

Part of the heater energy escaped to the surroundings. Using all of Pt as the energy gained makes the top of the fraction too large, so the calculated c is too high.