K323 / 2027
Light overview

Lesson 7 of 11

Optical fibres

  • I can explain optical fibres in telecommunications and medicine, including advantages.Syllabus

    Syllabus K323, 12(g). Explain optical fibres in telecommunications and medicine, including advantages.

Make a guess. You are not marked.

Light is sent into one end of a thin glass fibre that is bent into a gentle loop. Where does most of the light come out?

  1. At the far end of the fibre.
  2. Back at the end it went in, because the curved glass acts like a mirror.
  3. Through the side of the fibre at the first bend, because light travels in straight lines.
Show the answer

At the far end of the fibre.

Each time the light meets the wall of the fibre it is reflected back inside. It zigzags along the glass and follows the loop to the far end.

An optical fibre is a thin strand of glass that guides light by total internal reflection. Fibres carry phone and internet signals, and they let doctors see inside the body.

Total internal reflection needs two things. The light must travel from an optically denser medium towards a less dense one, and i must be greater than c.

How a fibre guides light

An optical fibre has a core with a higher refractive index. Around it is cladding with a lower refractive index. A ray inside the core meets the boundary between them above the critical angle. It is totally internally reflected, again and again, all the way along the fibre.

The core guides light by total internal reflection

In this fibre, ncore = 1.50 and ncladding = 1.40. The critical angle at the boundary between them is about 69.0°.

Two total internal reflections inside a straight optical-fibre coreA straight core of index 1.50 is bounded above and below by cladding of index 1.40. A ray inside the core travels right and reflects from the upper and then the lower core boundary. At each reflection it is 70 degrees to the local vertical normal, or 20 degrees to the horizontal fibre axis. This exceeds the 69.0 degree core-to-cladding critical angle. A dashed local normal and two equal angle arcs are drawn at the first reflection. The fibre continues beyond the cropped side edges; the final ray segment does not depict exit into air.NormalCladding: n = 1.4070°70°Core: n = 1.50At each bounce: 70° > 69.0°Fibre continues beyond the side edges

The critical angle depends on both materials. It is not the 41.8° of a boundary between glass and air.

The core has n = 1.50 and the cladding has n = 1.40. The critical angle at their boundary is about 69.0°. A ray in the core at 70° to the normal is totally internally reflected. This is a different boundary from the glass and air example.

For this fibre, 1.50 sin c = 1.40 sin 90°. So c = sin-1(1.40/1.50) = 69.0°. The ray shown meets the boundary at 70°, which is above c. Measure the angle of incidence from the normal, not along the wall of the fibre.

Check your understanding

The core of an optical fibre has a refractive index of 1.50. Which of these claddings lets the core guide light by total internal reflection?

  1. A cladding of refractive index 1.40.
  2. A cladding of refractive index 1.50.
  3. A cladding of refractive index 1.60.
Show the answer

A cladding of refractive index 1.40.

Total internal reflection needs light to travel from an optically denser medium towards a less dense one. The cladding must have a lower refractive index than the core.

Fibres in telecommunications

Pulses of light carry information along a fibre. Fibres have three advantages over copper cables that carry electrical signals.

  • Less signal loss. The signal fades less with distance (low attenuation), so a link can be very long.
  • More data. A fibre has a high bandwidth, so it carries much more information each second.
  • No electrical interference. Electromagnetic interference from nearby cables and machines does not disturb the light signal.

In 1966 Charles Kao and George Hockham proposed that glass fibres could be made clear enough for long links. Kao won the Nobel Prize in Physics in 2009. In Singapore, internet providers began to sell plans on a nationwide fibre network in 2010. By July 2013 it reached over 95% of homes and businesses.

Fibres in medicine

An endoscope lets a doctor look deep inside the body through an opening such as the mouth. The first endoscope with optical fibres was invented in 1957. The patient does not need a large cut.

One bundle of bendable fibres carries light in, to light up the part being examined. A second bundle carries the image back. Its fibres are in the same order at both ends, so the picture is not scrambled. Some modern endoscopes use an image sensor to take the picture.

Real fibres lose some light

Total internal reflection at a perfect boundary loses no light. A real fibre still loses some. The glass absorbs and scatters a little light, and joints between fibres lose more. A very sharp bend changes the angle of incidence, so light can escape there.

Light does not curve round the bends. Inside the core it travels in straight lines. It follows the fibre only because it reflects from the boundary again and again.

Check your understanding

A company replaces a copper telephone cable that runs beside electric power lines with an optical fibre. Which of these is an advantage of the fibre?

  1. The fibre carries a larger electric current than the copper cable.
  2. Electrical interference from the power lines does not disturb the light signal.
  3. Light in the glass travels faster than light in a vacuum, so signals arrive sooner.
Show the answer

Electrical interference from the power lines does not disturb the light signal.

The fibre carries pulses of light, not an electric current. Interference from nearby cables and machines does not affect them. A fibre also carries more data and loses less of the signal than copper.