9478 / 2027
Circuits overview

Lesson 15 of 15

Charge from a current-time graph

  • I can describe and represent charging/discharging current, charge and p.d. with exponential forms and time constant tau = RC.Syllabus

    Syllabus 9478, 16(l). Describe and represent charging/discharging current, charge and p.d. with exponential forms and time constant tau = RC.

Make a guess. You are not marked.

A capacitor discharges through 200 kilohm while a 10 megohm voltmeter reads its p.d. How does the measured time constant compare with RC for the resistor alone?

  1. Longer, because the meter adds extra resistance.
  2. A little shorter: the meter is a second path.
  3. Exactly RC, because a voltmeter draws no current.
Show the answer

A little shorter: the meter is a second path.

The meter is in parallel with the resistor, so the discharge resistance is 196 kilohm, not 200 kilohm. The time constant is about 2% shorter.

The area under a current-time graph is the charge that flows. For a capacitor, it equals the change in the charge on its plate.

With current positive towards plate B, a discharge has negative current. The area under the graph is negative too: it is ΔQ, the fall in the plate's charge. The amount that leaves is its size. The current graph from the last lesson shows this area.

Paper 4 practice: spreadsheet

Add up trapezia

In the same sheet, put =A3-A2 in G2 (interval / s) and =(F2+F3)*G2/2 in H2 (charge change / C). Copy both down to row 5 only: row 6 is the last point, so it has no interval after it.

Total area against the change in charge, 0 to 4 s
CellFormula
M5: trapezium sum / C=SUM(H2:H5)
M7: exact change / C=$L$2*$M$2*(EXP(-A6/$N$2)-1)
M8: relative excess=M5/M7-1
Compare the area with the change in charge

The four interval areas are -40.175, -24.375, -14.775 and -8.950 µC, a sum of -88.275 µC. The exact change is -86.4665 µC. The trapezia overestimate its size by about 2.09%, because the straight tops lie above the curve. Smaller intervals would do better. By 4 s the discharge is not complete, so less than the full 100 µC has left.

A real measurement

Record the switch time as t = 0, the sample times, R, and the starting p.d. Connect the voltage sensor across the capacitor. Check its zero, range and how often it samples. Keep the original record and note any reading you leave out, as in the measurement-record method.

A voltmeter across the capacitor is a second discharge path. A 10 MΩ meter in parallel with 200 kΩ gives:

R = (200 000 × 10 000 000)/(200 000 + 10 000 000)
= 196 078 Ω
τ = RC = 1.9608 s

That is about 2% shorter than 2.0 s. Dividing it by 200 kΩ would make C too small.

A real example. Energizer's datasheet gives the capacity of its E91 AA cell in milliamp-hours, measured by discharging it to 0.8 V. A milliamp-hour is a charge: 10-3 A × 3600 s = 3.6 C. It is the area under the cell's current-time graph.

Keep the sign of the current. In a discharge the area is negative, because the plate's charge falls. Do not drop the sign to make the charge look positive.

Check your understanding

A generated discharge trace gives signed current area -88.275 microcoulomb by 1 s trapezia over 0-4 s. The exact smooth model gives Delta Q = -86.4665 microcoulomb. How should the difference be interpreted?

  1. They estimate the charge change, but overestimate its size because the time intervals are coarse.
  2. The sign must be removed before calculating Delta Q, since charge cannot be negative.
  3. The excess magnitude proves the capacitor creates charge during discharge.
Show the answer

They estimate the charge change, but overestimate its size because the time intervals are coarse.

The current is negative in the stated reference. Straight-line interval areas overestimate the positive exponential magnitude here; refining the sampling reduces numerical error without changing charge conservation.