8867 / 2027
Nuclear Physics overview

Lesson 9 of 15

Uses of radioactivity

  • I can discuss medical and industrial uses and hazards using both half-life and penetrating and ionising properties.Syllabus

    Syllabus 8867, 11(j). Discuss medical and industrial uses and hazards using both half-life and penetrating and ionising properties.

Make a guess. You are not marked.

Why is gamma radiation, not alpha, used to sterilise syringes in sealed packs?

  1. Gamma is more strongly ionising than alpha, so it kills more bacteria.
  2. Gamma passes through the packaging to reach the syringes inside.
  3. Alpha would make the syringes radioactive, but gamma does not.
Show the answer

Gamma passes through the packaging to reach the syringes inside.

Gamma is very penetrating, so it reaches every part of the sealed pack and kills bacteria there. Alpha would be stopped by the packaging.

To choose a source, match two things to the job: its radiation, for how far it must travel and how much it must ionise, and its half-life, for how long it must last.

Thickness gauge

A beta source sits on one side of a moving sheet of paper or plastic, with a detector on the other. A thicker sheet absorbs more beta, so the count rate falls. Alpha would be stopped by any sheet, and gamma would pass almost unchanged. Only beta changes enough to show small changes in thickness.

The source needs a long half-life, so that its output stays steady for years. Otherwise a falling count from the source itself could be mistaken for a thicker sheet.

A partially transmitting sheet allows a thickness comparison

A partially transmitting sheet allows a thickness comparisonTwo schematic comparison rows use the same source and detector positions, identical incident direction and the same sheet centre.Same source and detector geometryβThinner sheetHigher rateSourceβThicker sheetLower rateSourceBoth cases allow partial transmission.

A thicker sheet absorbs more beta, so fewer reach the detector. Keep the source and detector fixed, and allow for the source decaying.

The source is inside; the detector receives photons outside

The source is inside; the detector receives photons outsideA schematic body outline contains a small internal tracer marker. Four gamma-photon direction arrows begin at that marker and leave in different directions; one reaches the external detector on the right.DetectorTracerOnly some emitted photonsreach the detector.

Only gamma photons that escape the body can reach the detector outside it.

Top: a thicker sheet lets fewer beta particles through. Bottom: gamma from a tracer inside the body reaches a detector outside.

Medical tracer

A tracer is injected or swallowed, and a camera outside the body shows where it goes. It must emit gamma, which escapes the body; alpha and beta would be absorbed inside. Its half-life should be a few hours: long enough for the scan, short enough to leave little activity behind.

Treatment and sterilisation

Gamma from outside the body can reach a tumour deep inside. The beam is aimed from several directions, so the tumour gets a large dose and healthy tissue gets less. Gamma also kills bacteria on syringes sealed in their packs, because it passes through the packaging.

A real example. The US EPA notes that some smoke detectors contain very small amounts of americium-241, mainly an alpha emitter. IAEA data give it a half-life of 432.6 years. Both suit the job. Alpha strongly ionises the air inside the detector but stops within a few centimetres of air, and the source hardly weakens during the detector's life.

Give both reasons. "Gamma, because it is penetrating" is only half an answer; also say why the half-life suits the job.

Check your understanding

A tracer inside a pipe must be detected from outside it, and at least half its initial activity must remain after 60 min. Which of these sources meets both conditions?

  1. An alpha emitter with a 2 h half-life.
  2. A gamma emitter with a 1 min half-life.
  3. A gamma emitter with a 2 h half-life.
Show the answer

A gamma emitter with a 2 h half-life.

It supplies photons and retains 2^(-60/120), about 0.707, of its activity after 60 min. Gamma photons pass through the pipe wall to the detector, so both conditions are met.