Lesson 8 of 15
Half-life from a decay curve
I can define half-life and solve problems using suitable quantities, tables or decay curves.Syllabus
Syllabus 8867, 11(i). Define half-life and solve problems using suitable quantities, tables or decay curves.
Make a guess. You are not marked.
Background is 4 counts/s. A detector sits beside a source with a short half-life. Will its total count rate ever fall to zero?
Show the answer
No, it levels off at about 4 counts/s.
The source's part keeps halving towards zero, but the background stays. So the total settles at the background rate.
A detector's reading includes background, so a decay curve levels off at the background rate, not at zero. Subtract the background first, then find the time for the corrected rate to halve.
In this model, the source gives 80 counts/s at the start and halves every 120 s. Background adds a steady 4 counts/s.
| t / s | Corrected / counts s-1 | Total / counts s-1 |
|---|---|---|
| 0 | 80 | 84 |
| 120 | 40 | 44 |
| 240 | 20 | 24 |
| 360 | 10 | 14 |
| 480 | 5 | 9 |
Total expected rate approaches the background
Background adds 4 counts/s at every time. At 120 s the total is 44 counts/s, not half of 84.
Corrected expected rate halves in equal times
Each halving takes 120 s, even though the second drop is smaller than the first.
Half of the first total, 84, is 42 counts/s. But after one half-life the total is 44 counts/s: 40 from the source plus 4 background. So halve the corrected rate, not the total.
The curve gets less steep as time goes on, because fewer nuclei are left to decay. It is not a straight line.
Read a half-life from a graph
- Read the background where the curve levels off.
- Subtract it from the reading at the start.
- Halve that corrected value, then add the background back.
- Read the time at which the curve reaches this value.
Repeat from a later starting point. Each half-life should come out about the same.
Graph reader
Find a half-life from measured counts
A detector records the total count rate from a source plus background. Move the time cursor to read the graph.
A real example. IAEA nuclear data give radon-222 a half-life of 3.82 days, and NEA names radon as one source of background. Seal some radon in a jar beside a detector. Its corrected count rate halves every 3.82 days, while the detector's total settles at the room's background.
Do not halve the raw reading. Halve the corrected rate, then add the background back before you read the graph.
Check your understanding
A detector's total count rate starts at 130 counts/min and levels off at a background of 30 counts/min. What total reading shows that one half-life has passed?
Show the answer
80 counts/min.
The source gives 130 - 30 = 100 counts/min at the start. After one half-life it gives 50, and the detector adds the 30 background: 50 + 30 = 80.