Lesson 4 of 8
Ammeters and voltmeters
I can define current as the rate of charge flow and state its ampere unit.Syllabus
Syllabus K323, 14(a). Define current as the rate of charge flow and state its ampere unit.
I can define potential difference across a component as work per charge through it, measured in volts.Syllabus
Syllabus K323, 14(f). Define potential difference across a component as work per charge through it, measured in volts.
Make a guess. You are not marked.
By mistake, a student connects a voltmeter in series with a lamp and a cell. The voltmeter has a very high resistance. What happens?
Show the answer
The lamp stays off, because almost no current can flow through it.
The voltmeter's very high resistance is now in the only path, so the current is tiny. The lamp needs a much larger current to glow.
An ammeter goes in series to measure the current through a component. A voltmeter goes in parallel, across the component, to measure the p.d.
Current is the charge passing a point each second. P.d. is the energy transferred per coulomb between two points.
An ammeter goes in series
An ammeter is drawn as a circle with an A inside. To measure the current through a lamp, break the circuit next to the lamp and put the ammeter in the gap. Now all of the lamp's current passes through the meter. This is a series connection: the parts are joined one after another, in one path.
An ammeter has a very low resistance, so it hardly changes the current it measures. Never connect it straight across a cell or a lamp. It would give the current an easy path round them, and a very large current could flow.
A voltmeter goes in parallel
A voltmeter is drawn as a circle with a V inside. Connect one lead to each end of the component. This is a parallel connection: the meter sits across the component, beside the main path.
A voltmeter has a very high resistance, so it takes almost no current. That is why it must not go in series. There, it would let almost no current through, and the lamp would stay off.
Measure current through and p.d. across the same resistor
A is an ammeter in series. V is a voltmeter joined to the two ends of the resistor. The + signs show which way round to connect each meter.
Readings: 0.20 A through the resistor and 6.0 V across it.
We treat both meters as ideal. The voltmeter takes almost no current, and the ammeter has almost no p.d. across it. So the ammeter reads the current in the resistor.
Get the connections and the range right
For d.c., join each meter's + terminal to the side nearer the cell's + terminal. On a meter with a needle, a needle that tries to go below zero means the leads are swapped.
Pick a range bigger than the reading you expect. A 0-5 V range cannot show 6.0 V. If you are unsure, start on the largest range. Then switch down to the smallest range that still fits, for a more exact reading.
Read a needle scale with your eye straight in front of the needle. This avoids parallax error, a wrong reading caused by looking at the scale from an angle.
Early current meters used an effect found by Hans Christian Oersted in 1820. A current in a wire makes a nearby compass needle turn. Today one digital multimeter can be set to work as an ammeter or a voltmeter.
Do not swap the meters. A voltmeter in series stops the current. An ammeter across a component lets a large current flow round it.
Check your understanding
Which of these connections measures the current through a lamp and the p.d. across it?
Show the answer
An ammeter in series with the lamp, and a voltmeter joined across the two ends of the lamp.
The lamp's current must pass through the ammeter, so it goes in series. The p.d. is measured between the lamp's two ends, so the voltmeter goes in parallel with the lamp.