9478 / 2027
Thermodynamic Systems overview

Lesson 9 of 9

Measuring specific latent heat

  • I can define and use specific heat capacity and specific latent heat.Syllabus

    Syllabus 9478, 13(g). Define and use specific heat capacity and specific latent heat.

Make a guess. You are not marked.

A student melts ice with a heater to find l_f, but uses no control funnel. She divides the heater energy by all the water collected. How does her value compare with the true value?

  1. About right, because the room melts ice at a steady rate.
  2. Too large, because the energy from the room adds to the heater's.
  3. Too small, because some of the water was melted by the room.
Show the answer

Too small, because some of the water was melted by the room.

Energy from the room melts extra ice, so the mass she divides by is too big. Dividing by too big a mass gives too small an l_f.

Melt ice with a known amount of electrical energy, then weigh the extra water it makes. This gives the specific latent heat of fusion.

The method

Fill two funnels with crushed ice at 0 °C. One has an electric heater in it; the other has none and is the control. Let the water already melted drain away. Then, for the same time, switch on the heater and collect the water dripping from each funnel. Weigh both.

The control collects water melted by energy from the room. The heated funnel gets the same energy from the room, plus the heater's. So the extra water from the heated funnel was melted by the heater alone.

A heated run and a control run

Both funnels start with ice at 0 °C. Water already melted is drained away, then meltwater is collected for 300 s in each.

Heater-on collection

With a 16.7 W heater, 20.00 g of water is collected in 300 sA funnel of ice at 0 degrees drains into a beaker on a balance. A heater in the ice gives 16.7 watts for 300 seconds, and 20.00 grams of water is collected.Collect for 300 sHeater on16.7 WIce at 0 °CMatchedbackgroundSupportTaredcollector20.00 g

Control: heater off

Without the heater, 5.00 g is collected in 300 sA funnel of ice at 0 degrees drains into a beaker on a balance. The heater is off, and 5.00 grams of water is collected from heat taken in from the room.Collect for 300 sHeater off0 WIce at 0 °CMatchedbackgroundSupportTaredcollector5.00 g

The heater melts an extra 20.00 - 5.00 = 15.00 g using 16.7 × 300 = 5010 J. So lf = 5010/0.01500 = 3.34 × 105 J/kg.

This works only if both runs gain the same energy from the room and all the meltwater is collected.

Both funnels collect meltwater for 300 s. The heated one collects 20.00 g and the control 5.00 g.

Worked example

From the readings to lf

The heater gives 16.7 W for 300 s. The heated funnel collects 20.00 g of water and the control collects 5.00 g.

Heater energy = 16.7 × 300 = 5010 J
Extra mass melted = 20.00 - 5.00 = 15.00 g = 0.015 00 kg
lf = 5010/0.015 00 = 3.34 × 105 J/kg

Check your understanding

A heater supplies 6000 J to ice at 0 degrees C, and 28.0 g of water is collected. A control funnel collects 10.0 g in the same time. What is the specific latent heat of fusion?

  1. 3.33 x 105 J/kg
  2. 2.14 x 105 J/kg
  3. 1.58 x 105 J/kg
Show the answer

3.33 x 105 J/kg

The heater melted 28.0 - 10.0 = 18.0 g. So l_f = 6000/0.0180 = 3.33 x 105 J/kg.

What can go wrong

  • Ice colder than 0 °C: some of the heater's energy warms the ice instead of melting it, so lf comes out too high.
  • Water left in the funnel: less water is weighed than was melted, so lf again comes out too high.
  • Unequal funnels: if the two funnels gain energy from the room at different rates, subtracting the control no longer works.

Subtract the control's water before you divide. Dividing the heater energy by all the water collected makes lf too small.