9478 / 2027
Thermodynamic Systems overview

Lesson 6 of 9

Measuring specific heat capacity

  • I can define and use specific heat capacity and specific latent heat.Syllabus

    Syllabus 9478, 13(g). Define and use specific heat capacity and specific latent heat.

To measure c, supply a known amount of electrical energy and measure the temperature rise. Then allow for energy that warms the apparatus or escapes.

The method

Weigh the sample. Put an electric heater and a thermometer in it, inside an insulated vessel. Switch on for a measured time and record the heater's power, so the energy supplied is E = Pt. Stir a liquid so it all has one temperature. Record the temperature rise, including the highest reading after the heater is switched off.

Where the energy goes

Not all of the energy supplied warms the sample. Some warms the vessel, heater and thermometer, and some escapes to the room.

Where does the heater's energy go?

The dashed line surrounds the sample, heater, vessel and thermometer. The heater supplies 6000 J; some energy is lost to the room.

The heater warms the sample and the apparatus, and some energy escapesA dashed line surrounds a 0.250 kg sample, its vessel, a heater and a thermometer. An arrow shows 6000 joules going in through the heater, and another shows energy lost to the room.Calibratedwork input6000 JSensorSample0.250 kgHeaterLoss680 JSettled rise: 8.0 KAssembly boundary

Of the 6000 J, 680 J is lost to the room and 40 × 8.0 = 320 J warms the vessel and heater. That leaves 5000 J for the sample.

Count the heater's energy once. Do not add it again as a separate input.

The heater supplies 6000 J. Some warms the apparatus and some is lost to the room; the rest warms the sample.

Worked example

Allowing for the apparatus and the loss

A 0.250 kg sample warms by 8.0 K while the heater supplies 6000 J. The apparatus has a heat capacity of 40 J/K and warms by the same 8.0 K. About 680 J escapes to the room.

Energy to apparatus = 40 × 8.0 = 320 J
Energy to sample = 6000 - 320 - 680 = 5000 J
c = 5000/(0.250 × 8.0) = 2500 J/(kg K)

Giving all 6000 J to the sample would give c = 6000/(0.250 × 8.0) = 3000 J/(kg K), which is 20% too high.

Try it step by step

Work it out in steps: Energy supplied by the heater Pt in J, then Energy that reached the sample (supplied minus losses) in J, then Specific heat capacity c = E / (m x temperature rise) in J/(kg K).

  1. Problem 1. A 40 W heater runs for 300 s in a 0.50 kg sample, which warms by 24 K. An estimated 1500 J is lost to the surroundings. Find the specific heat capacity.
  2. Problem 2. A 25 W heater runs for 400 s in a 1.0 kg sample, which warms by 10 K. An estimated 1000 J is lost. Find the specific heat capacity.
  3. Problem 3. A 50 W heater runs for 240 s in a 0.40 kg sample, which warms by 60 K. An estimated 2400 J is lost. Find the specific heat capacity.
Show the answer

Problem 1.

Energy supplied by the heater Pt in J: E supplied = 40 x 300 = 12000 J

Energy that reached the sample (supplied minus losses) in J: E to sample = 12000 - 1500 = 10500 J

Specific heat capacity c = E / (m x temperature rise) in J/(kg K): c = 10500 / (0.50 x 24) = 875 J/(kg K) (3 sf)

Problem 2.

Energy supplied by the heater Pt in J: E supplied = 25 x 400 = 10000 J

Energy that reached the sample (supplied minus losses) in J: E to sample = 10000 - 1000 = 9000 J

Specific heat capacity c = E / (m x temperature rise) in J/(kg K): c = 9000 / (1.0 x 10) = 900 J/(kg K) (2 sf)

Problem 3.

Energy supplied by the heater Pt in J: E supplied = 50 x 240 = 12000 J

Energy that reached the sample (supplied minus losses) in J: E to sample = 12000 - 2400 = 9600 J

Specific heat capacity c = E / (m x temperature rise) in J/(kg K): c = 9600 / (0.40 x 60) = 400 J/(kg K) (2 sf)

Check your understanding

A 0.250 kg sample warms by 8.0 K during a 6000 J input. Independently supplied corrections are 320 J for apparatus warming and 680 J lost to the surroundings. With no phase change or significant volume work, what is the sample's specific heat capacity?

  1. 3500 J/(kg K), adding the corrections to the measured input.
  2. 2500 J/(kg K), using the 5000 J that reached the sample.
  3. 3000 J/(kg K), because every joule measured must raise the sample temperature.
Show the answer

2500 J/(kg K), using the 5000 J that reached the sample.

The sample receives 6000 - 320 - 680 = 5000 J. Thus c = 5000/(0.250 x 8.0) = 2500 J/(kg K). Assigning all 6000 J to it would give 3000, which is too high.

Cancelling the heat loss

The rate of energy loss depends on the temperature of the sample. So heat the sample at two powers, P1 and P2. Each time, measure how fast the temperature rises, r1 and r2, as it passes the same temperature. The loss rate is then the same both times, so it cancels when you subtract:

P2 - P1 = mc(r2 - r1)

Ignoring the heat loss gives the sample too much energy in your working, so c comes out too high.