Lesson 5 of 7
Titration and quantitative analysis
Make the measured volume correspond to the reacting amount.
SEC G2 Science K223 / K225 (2027)
I can select and use techniques, apparatus and materials.Syllabus
Syllabus K223 / K225, C1. Select and use techniques, apparatus and materials
Make a titre correspond to the reacting amounts
The endpoint, rinsing and complete transfer determine what the number means.
- Prepare the measured solutions
Rinse the burette with its solution and the pipette with the solution it will measure. Fill the burette tip, remove the funnel and record the initial reading. Use a pipette filler.
- Transfer a fixed aliquot
Deliver the pipetted solution into a clean conical flask. Allow the pipette to drain as designed; do not blow out a residual tip drop unless it is a blow-out pipette.
- Locate the endpoint
Add a small consistent amount of a suitable indicator. Swirl during addition, use a white background and add titrant dropwise near the endpoint. Rinse flask walls with distilled water if needed.
- Repeat and calculate
Record the final reading and titre. Obtain agreeing precise titres, select a justified mean, then use concentration, volume and the balanced mole ratio.
The equivalence point is the stoichiometric completion of reaction. The endpoint is the observed indicator change. Choose an indicator that changes colour within the steep pH change near equivalence. Universal indicator gives a broad colour change, so it is unsuitable for a precise titration. The required final colour depends on the indicator and which solution is added.
The burette has a long history. The German chemist Karl Friedrich Mohr made it much easier to use by giving it a tip and a clamp at the bottom. In 1855 he published the first textbook on titration.
Check your understanding
After pipetting the alkali into the conical flask, a student adds a little distilled water. How does this affect the titre?
Show the answer
No effect, because the amount of alkali in the flask is unchanged.
Water dilutes the alkali but does not change the moles present, so the same volume of acid neutralises it. This assumes nothing is lost and the end-point is still clear.
Check your understanding
Why is universal indicator not used to find the end-point of an acid-alkali titration?
Show the answer
Its colour changes gradually over a wide pH range, so there is no sharp end-point
A titration needs one sudden colour change at the end-point. Universal indicator passes through many colours as the pH changes, so you cannot tell exactly when to stop.
Watch out for this
A student says: "In a titration, the acid is added from a pipette, a little at a time, until the indicator changes colour." What is wrong with this?
Show the answer
The acid is added from a burette. A burette delivers any volume and lets you read how much was added. A pipette delivers one fixed volume, so it is used to put the alkali into the flask. Examiners report students swapping the burette and the pipette.