Lesson 5 of 6
Measuring electrical power
I can use potential difference as electrical work done per unit charge, V = W/Q.Syllabus
Syllabus 8867, 8(c). Use potential difference as electrical work done per unit charge, V = W/Q.
I can recall and use P = VI, P = I^2 R and P = V^2/R for electrical power.Syllabus
Syllabus 8867, 8(d). Recall and use P = VI, P = I^2 R and P = V^2/R for electrical power.
Make a guess. You are not marked.
A joulemeter connected to a kettle shows an increase of 180 kJ in 60 s. What is the kettle's average power?
Show the answer
3.0 kW, because power is energy divided by time.
Power = energy / time = 180000 J / 60 s = 3000 W = 3.0 kW.
To measure the power to a component, put an ammeter in series with it and a voltmeter across it. Then P = VI, and the energy over time t is VIt.
Place and choose the meters
An ammeter must carry the component's current, so it goes in series. A voltmeter compares the two ends of the component, so it goes across it. A good ammeter has a very small resistance; a good voltmeter has a very large one. Then the meters hardly change the circuit.
Estimate the readings first. A 30.0 Ω resistor on about 6.00 V takes about 6/30 = 0.2 A. So a 0 to 0.1 A range is too small, while a 0 to 1 A range may do if its resolution is fine enough. Check the zero and the polarity too.
Measure the chosen resistor, between P and Q
The ammeter is in series; the voltmeter is across P and Q. Assume the meters do not change the circuit.
The selected load receives 1.20 W, or 48.0 J over 40.0 s if both readings stay steady. This is the 30.0 Ω bench model; it is separate from the 3.00 Ω power-calculation example.
Worked measurement
Steady readings for 40.0 s
P = VI = 6.00 × 0.200 = 1.20 W
W = VIt = 1.20 × 40.0 = 48.0 J
Watch for readings that drift as the resistor warms. Switching off between readings helps, but does not prove the resistance stayed the same.
V, I and t give the electrical energy delivered to the resistor. They do not, on their own, measure any useful output.
A real example. SP Group's connection handbook says that all meters measuring a customer's electricity consumption are provided and maintained by SP. Each one is a kWh meter: it adds up the energy delivered, which the bill then charges for.
Do not put a voltmeter in series. Its very large resistance almost stops the current, so the circuit no longer behaves as it should.
Check your understanding
You want to measure the power delivered to a resistor. Which of these meter arrangements is correct?
Show the answer
Ammeter in series; voltmeter across the resistor.
The ammeter must carry the same current as the resistor, so it goes in series. The voltmeter compares the two ends of the resistor, so it goes across it. Then P = VI.