K323 / 2027
Radioactivity overview

Lesson 7 of 11

Finding half-life from readings and graphs

  • I can use half-life in simple calculations, tables and decay curves.Syllabus

    Syllabus K323, 20(h). Use half-life in simple calculations, tables and decay curves.

Make a guess. You are not marked.

A detector is placed near a radioactive source with a short half-life, and its total count rate is recorded for a long time. What happens to the total count rate in the end?

  1. It levels off at the background count rate.
  2. It keeps falling by the same number of counts in every half-life.
  3. It falls to zero once the source has decayed.
Show the answer

It levels off at the background count rate.

The part from the source keeps halving towards zero, but the background radiation stays. So the total settles at the background, not at zero.

To find a half-life from readings, first take away the background. Then find the time for the corrected count rate to halve.

Half-life is the time for the count rate from a source to halve.

From a table

A detector near a source gives these total count rates. The background is 20 counts/min.

Take the same background from each total.
Time / minTotal / (counts/min)Corrected / (counts/min)
0180160
410080
86040
124020
163010

Take away the background before finding the half-life

A smooth model of one source, with a steady background of 20 counts/min. Real readings scatter around such a curve.

Total count rate includes the background

Total count rate includes the backgroundCount rate in counts per minute against time in minutes. The total count rate is 180 at 0 min, 100 at 4 min, 60 at 8 min, 40 at 12 min and 30 at 16 min. A dashed line marks the background of 20 counts per minute. The curve levels off towards this line, not towards zero.Count rate / counts per min02040801201602000481216Time / min

The dashed line is the 20 counts/min background. The total curve approaches that level, rather than zero.

Corrected count rate: subtract 20 counts/min

Corrected count rate: subtract 20 counts/minOn the same axes, the corrected count rate is 160, 80, 40, 20 and 10 counts per minute at 0, 4, 8, 12 and 16 min. Two shaded intervals, 0 to 4 min and 8 to 12 min, each last 4 min: 160 halves to 80, and 40 halves to 20.Count rate / counts per min02040801201602000481216Time / min4 min160 to 804 min40 to 20

160 to 80 and 40 to 20 counts/min each take 4 min. The corrected rate gets closer and closer to zero.

Both graphs use the same scales. Each dot is a value from the table.

The total curve levels off at the background of 20 counts/min. The corrected curve heads towards zero.
  1. Correct the readings: 180 - 20 = 160 and 100 - 20 = 80 counts/min.
  2. Find the time to halve: 160 to 80 takes 4 min.
  3. Check another pair: 40 at 8 min to 20 at 12 min also takes 4 min. So the half-life is 4 min.

Halving the total instead, from 180 to 90, would halve the background too. The background does not decay, so the answer would be wrong.

From a graph

Pick a corrected count rate on the curve and find half of it. Read the time between the two. Do the same for a second pair to check, and draw the lines on the graph to show your working.

Real readings scatter above and below a smooth curve, because decay is random. Draw a smooth curve of best fit through them.

Ernest Rutherford discovered the principle of half-life in 1907.

Graph reader

Find a half-life from measured counts

A detector records the total count rate from a source plus background. Move the time cursor to read the graph.

050100150200250300051015202530time / mincount rate / (counts/min)

Correct before you halve. Take the background away from each reading first. Halving the raw readings gives the wrong half-life.

Check your understanding

A single-nuclide model has background 20 counts/min. Its total rates are 180 counts/min at 0 min, 100 at 4 min and 60 at 8 min. What half-life follows from these readings?

  1. It cannot be found until the total rate reaches zero.
  2. 4 min: the corrected rate falls from 160 to 80, then from 80 to 40 counts/min.
  3. Between 4 and 8 min, when the total rate falls from 180 to 90 counts/min.
Show the answer

4 min: the corrected rate falls from 160 to 80, then from 80 to 40 counts/min.

Both corrected halving intervals last 4 min under unchanged detection conditions. Equal time intervals halve the remaining source contribution; they do not subtract an equal number of counts each time.