K323 / 2027
Radioactivity overview

Lesson 10 of 11

Choosing a source for the job

  • I can discuss medical and industrial applications and hazards using both half-life and the penetration and ionisation of emissions.Syllabus

    Syllabus K323, 20(i). Discuss medical and industrial applications and hazards using both half-life and the penetration and ionisation of emissions.

Make a guess. You are not marked.

A gamma tracer is injected into a patient for a scan that takes a few hours. Which half-life suits the tracer best?

  1. About 6 years.
  2. About 6 minutes.
  3. About 6 hours.
Show the answer

About 6 hours.

That is long enough for the scan to finish, and short enough that the activity falls to a low level within a day or two.

To choose a radioactive source for a job, check two things: the radiation it gives out, and its half-life.

Each use needs radiation that gets through the right amount of matter. Half-life sets how quickly a source's activity falls.

Two questions to ask

Does the radiation get where it must?
A tracer read from outside the body needs gamma. A paper gauge needs beta. A smoke alarm needs alpha to ionise the air.
Is the half-life right for the job?
It must be long enough for the job. A tracer's half-life should also be short, so that it does not stay active in the body for long. A factory gauge needs a long half-life, so that its source lasts for years.

Over 50 million nuclear medicine procedures are done around the world each year, and about 80% of them use technetium-99m. It gives out gamma rays that a camera can detect, and its half-life is about 6 hours. That is long enough for a scan, and short enough to keep the patient's dose low.

Use the numbers you are given

Which tracer for a 2-hour test of a pipe?

A detector at the end of a pipe follows a tracer. Each source starts at a corrected count rate of 1600 counts/min and gives out a suitable radiation. At least 400 counts/min must be left after 2 h, and the source should not stay active for long afterwards.

R: half-life 20 min
2 h = 120 min, which is six half-lives. The rate falls to 1600/64 = 25 counts/min, below 400. Too short.
S: half-life 2 h
One half-life leaves 800 counts/min, which is enough. It then keeps halving over the next hours.
T: half-life 8 days
It has plenty of activity for the test, but stays active for weeks afterwards.

S is the best choice.

Use both properties. Explain the choice of radiation and of half-life, and say why each other source is worse. The shortest half-life is not always best.

Check your understanding

A pipe tracer must still give at least 400 counts/min (corrected) after 2 h. Sources R, S and T each start at 1600 counts/min and emit a suitable radiation. Their half-lives are 20 min, 2 h and 8 days. Which source meets the task without staying active for long afterwards?

  1. S, with a half-life of 2 h.
  2. T, with a half-life of 8 days.
  3. R, with a half-life of 20 min.
Show the answer

S, with a half-life of 2 h.

One half-life leaves 800 counts/min after 2 h, which meets the requirement. It then keeps halving, so within a day it has fallen to a tiny fraction of its starting rate.