Lesson 7 of 8
Transformer calculations
I can apply the ideal voltage/turns ratio and input/output power equations.Syllabus
Syllabus K323, 19(e). Apply the ideal voltage/turns ratio and input/output power equations.
In a transformer, the voltages are in the same ratio as the numbers of turns. In an ideal transformer, the power out equals the power in.
A transformer has a primary (input) coil and a secondary (output) coil on one iron core. Electrical power is P = VI.
The two equations
N is the number of turns on a coil, V is the voltage across it and I is the current in it. The letter p means primary and s means secondary.
An ideal transformer wastes no energy. Real ones waste a little, so their power out is a little less than their power in.
Step down: 240 V to 12 V
Voltage first, then power
1000 primary turns and 50 secondary turns
Vs = Vp x Ns/Np = 240 x 50/1000 = 12.0 V.
The load takes Is = 2.0 A, so the power out = 12.0 x 2.0 = 24 W.
Ideal, so the power in is also 24 W. Ip = 24/240 = 0.100 A.
The secondary, at the lower voltage, carries the larger current.
Step up: 12 V to 60 V
Same power, higher voltage
200 primary turns and 1000 secondary turns
Vs = 12 x 1000/200 = 60 V.
The transformer passes on 30 W. Ip = 30/12 = 2.5 A and Is = 30/60 = 0.50 A.
The voltage goes up five times and the current goes down five times. The transformer does not make extra energy.
Singapore's mains supply is 230 V. To get 12 V from it, a transformer needs Np/Ns = 230/12, which is about 19. So its primary has about 19 times as many turns as its secondary.
Try it step by step
Work it out in steps: Secondary voltage Vs = Vp x Ns / Np in V, then Secondary current Is = P / Vs in A, then Primary current Ip = P / Vp in A.
Show the answer
Problem 1.
Secondary voltage Vs = Vp x Ns / Np in V: Vs = 240 x 100 / 2000 = 12 V
Secondary current Is = P / Vs in A: Is = 24 / 12 = 2.0 A
Primary current Ip = P / Vp in A: Ideal, so input power = output power: Ip = 24 / 240 = 0.10 A
Problem 2.
Secondary voltage Vs = Vp x Ns / Np in V: Vs = 230 x 50 / 1150 = 10 V
Secondary current Is = P / Vs in A: Is = 20 / 10 = 2.0 A
Primary current Ip = P / Vp in A: Ip = 20 / 230 = 0.087 A (2 sf)
Problem 3.
Secondary voltage Vs = Vp x Ns / Np in V: Vs = 12 x 2000 / 100 = 240 V
Secondary current Is = P / Vs in A: Is = 60 / 240 = 0.25 A
Primary current Ip = P / Vp in A: Ip = 60 / 12 = 5.0 A
The two currents are not equal. Many answers find the secondary current and stop, or use it for the primary. The coil at the higher voltage carries the smaller current. Write "ideal transformer, so power in = power out" before you use it.
Check your understanding
An ideal transformer has 1000 primary turns and 50 secondary turns. Its primary voltage is 240 V, and a connected resistive load takes 2.0 A from the secondary. What are the secondary voltage and primary current?
Show the answer
12 V and 0.100 A
Vs = 240 x 50/1000 = 12 V. For the ideal model, input power equals the 12 x 2.0 = 24 W output, so Ip = 24/240 = 0.100 A.