Lesson 6 of 7 / Respiration in humans
Measuring the rate of respiration
How can a moving drop of liquid show how fast seeds respire?
I can explain how a respirometer measures oxygen uptake, and why small mammals respire faster for their size.
I can define aerobic respiration and give both equations.Syllabus
Syllabus K325, Topic 6(e). Define aerobic respiration and give both equations.
About 4 min
Make a guess. You are not marked.
Seeds in a sealed tube take in oxygen and give out carbon dioxide. A chemical in the tube absorbs the carbon dioxide. What happens to the amount of gas in the tube?
Show the answer
It falls.
Oxygen is taken in and the carbon dioxide released is absorbed, so less gas is left in the tube.
The key idea
In a respirometer, organisms take in oxygen and sodium hydroxide absorbs the carbon dioxide they release. The gas volume falls, so the drop moves towards the organisms.
A respirometer is an apparatus that measures how fast living organisms take in oxygen. Faster respiration uses oxygen faster.
Illustrative values, not measured data.
Explanation
Germinating seeds or woodlice sit in a sealed tube above sodium hydroxide solution. A capillary tube, which is a very narrow glass tube, is attached. It holds a coloured drop of liquid.
The organisms respire aerobically. They take in oxygen and release carbon dioxide. The sodium hydroxide absorbs the carbon dioxide, so the volume of gas in the tube falls. The drop moves towards the organisms.
The distance the drop moves per minute measures the rate of oxygen uptake. Faster respiration moves the drop faster.
A control tube holds glass beads of the same volume in place of the living organisms. Its drop should not move. This shows that the first drop moves only because of respiration, not because of a change in temperature or air pressure.
Sodium hydroxide is corrosive. It is kept below a gauze where the organisms cannot touch it.
Small mammals respire faster for their size. A mouse has a much larger surface area to volume ratio than a human. So it loses heat to its surroundings faster for each gram of body mass. To keep its body temperature constant, its cells respire faster per gram and release more heat. A mouse therefore takes in oxygen faster per gram than a large mammal. The Etruscan shrew is the smallest mammal by mass, at about 1.8 g. Each day it must eat 1.5 to 2 times its own body mass in food.
Step by step
- 1
Seal the organisms in
Living organisms sit above sodium hydroxide in a sealed tube joined to a capillary tube.
- 2
Follow the gases
Oxygen is taken in. Carbon dioxide is released and absorbed, so the gas volume falls.
- 3
Measure the drop
Rate = distance moved / time. Compare with the glass-bead control.
Worked example
Compare two temperatures
In an invented experiment, the drop in a respirometer with germinating seeds moves 12 mm in 6 minutes at 15 degrees C and 36 mm in 6 minutes at 25 degrees C. The drop in a glass-bead control does not move at either temperature. Calculate both rates and say what they show.
One way to explain it
At 15 degrees C the rate is 12 / 6 = 2.0 mm/min. At 25 degrees C it is 36 / 6 = 6.0 mm/min. The seeds take in oxygen three times as fast at 25 degrees C, so they respire faster. The control shows that the living seeds caused the movement.
Why this answer works
- Rate = distance / time, with the unit mm/min.
- A faster drop means faster oxygen uptake.
- The control rules out a change in temperature or pressure as the cause.
Watch out for this
A student says: "The drop moves because the seeds release carbon dioxide into the tube." What is wrong with this?
Show the answer
The carbon dioxide is absorbed by sodium hydroxide, so it adds no gas. The drop moves towards the seeds because oxygen is taken in and the gas volume falls.
Check your understanding
In a respirometer, the drop in the tube with germinating seeds moves 20 mm towards the seeds. In the same time, the drop in the glass-bead tube also moves 20 mm the same way. What should the student conclude?
Show the answer
Something other than respiration moved the drops, so the result cannot be used.
Glass beads do not respire. If the control drop moves just as far, a change such as cooling moved both drops.
Quick recall
How can a moving drop of liquid show how fast seeds respire?