K223 / K224 / 2027
Radioactivity overview

Lesson 4 of 8

Background radiation and count rate

  • I can explain background radiation and account for it when interpreting detector readings.Syllabus

    Syllabus K223 / K224, 13(f). Explain background radiation and account for it when interpreting detector readings.

In short

  • Background radiation is all around us, from rocks, cosmic rays, food and the air.
  • Measure the background count rate with no source, then subtract it from each reading.
  • Count rate = counts / time, for example in counts per minute.

A detector picks up some radiation even when no source is near. This background radiation must be taken away from every reading.

Decay is random, so the count goes up and down from one reading to the next.

Where background radiation comes from

  • Rocks, soil and buildings, including radon gas from the ground.
  • Cosmic rays from space.
  • Food: bananas and potatoes are slightly radioactive.
  • Man-made sources, mostly from medicine.

In Singapore, NEA runs 40 stations that measure radiation in the air and water. The background level varies a little from place to place, with the radioactive materials in soil, rock and buildings.

Count rate

Count rate = number of counts / counting timeFor example, in counts/min or counts/s.

Five one-minute readings with no source give 18, 21, 19, 22 and 20 counts. That is 100 counts in 5 min, so the background count rate is 100/5 = 20 counts/min.

Turn counts into rates, then subtract

The counter shows a number of counts. Divide it by the counting time to get a count rate. Teal arrows show some of the radiation.

Background only: 100 counts in 5 min

Background only: 100 counts in 5 minNo source is present. Dashed arrows show background radiation reaching the detector. The counter shows 100 counts in 5 minutes, which is 20 counts per minute.BackgroundNo sourcepresentDetectorCounter total100 countsCounting time / min012345100 / 5 = 20 counts/min

Source plus background: 300 counts in 2 min

Source plus background: 300 counts in 2 minThe source is now next to the same detector, and background radiation still arrives. The counter shows 300 counts in 2 minutes, which is 150 counts per minute. Taking away 20 counts per minute of background leaves 130 from the source.BackgroundSourcepresentDetectorCounter total300 countsCounting time / min012345300 / 2 = 150 counts/min

Source rate = 150 - 20 = 130 counts/min. Subtract rates, not counts, because the two counts took different times.

The two counts took different times, so turn each into a rate before you subtract.

Subtract rates, not counts

300 counts in 2 min with the source

  1. Total rate: 300/2 = 150 counts/min.
  2. Background rate: 100/5 = 20 counts/min.
  3. Corrected count rate: 150 - 20 = 130 counts/min from the source.

Try it step by step

Work it out in steps: Background rate in counts/min, then Rate with the source present in counts/min, then Corrected source rate in counts/min.

  1. Problem 1. With no source present, a detector records 150 counts in 5 minutes. With a source in place it records 420 counts in 2 minutes. Find the count rate due to the source alone.
  2. Problem 2. With no source present, a detector records 120 counts in 4 minutes. With a source in place it records 900 counts in 3 minutes. Find the count rate due to the source alone.
  3. Problem 3. With no source present, a detector records 200 counts in 10 minutes. With a source in place it records 630 counts in 3 minutes. Find the count rate due to the source alone.
Show the answer

Problem 1.

Background rate in counts/min: Background = 150 / 5 = 30 counts/min

Rate with the source present in counts/min: With source = 420 / 2 = 210 counts/min

Corrected source rate in counts/min: Source alone = 210 - 30 = 180 counts/min

Problem 2.

Background rate in counts/min: Background = 120 / 4 = 30 counts/min

Rate with the source present in counts/min: With source = 900 / 3 = 300 counts/min

Corrected source rate in counts/min: Source alone = 300 - 30 = 270 counts/min

Problem 3.

Background rate in counts/min: Background = 200 / 10 = 20 counts/min

Rate with the source present in counts/min: With source = 630 / 3 = 210 counts/min

Corrected source rate in counts/min: Source alone = 210 - 20 = 190 counts/min

Fair readings

Keep the detector, its distance from the source and its settings the same for every reading. Count for longer, or repeat the count, to even out the random ups and downs.

Beyond the syllabus: activity in becquerels (not examined)

The activity of a source is the number of its nuclei that decay each second. Its unit is the becquerel, Bq: 1 Bq is one decay per second.

A detector catches only some of the radiation, so its count rate is smaller than the activity. A count rate of 80 counts/s does not mean an activity of 80 Bq.

Correct every reading. Take the background count rate away from each reading before you use it. Removing the source does not make the reading zero.

Check your understanding

A background measurement records 100 counts in 5.0 min. With the source present, the same setup records 300 counts in 2.0 min. What is the estimated net source count rate?

  1. 130 counts/min
  2. 200 counts/min
  3. 150 counts/min
Show the answer

130 counts/min

The source-plus-background rate is 150 counts/min. Subtract the mean background rate of 20 counts/min to estimate 130 counts/min from the source. A separate calibration is needed to turn this detector rate into an activity estimate.