Lesson 4 of 8
Measuring a rate
Choose a signal that follows one species and find an initial rate.
A-Level 9476 (2026-2027)
I can devise a suitable rate experiment.Syllabus
Syllabus 9476, 8(e). Devise a suitable rate experiment.
Choose a signal that follows a changing species
The method must be fast enough, selective enough and controlled enough for the question.
| Observable change | Possible method | Key control or limitation |
|---|---|---|
| Gas produced | Record gas-syringe volume against time, or loss of mass if gas escapes. | Check for leaks, gas solubility and temperature/pressure changes; account for mixing delay. |
| Coloured species consumed or formed | Record absorbance with a colorimeter at a suitable wavelength. | Calibrate absorbance against concentration; use a blank and avoid interference from other coloured species. |
| Acid, base or redox species changes | Withdraw timed aliquots, quench if needed, then titrate. | Quenching must stop the reaction without changing the amount being analysed. |
| A small fixed amount of product triggers a colour change | Use a clock method and measure time to the same endpoint. | 1/time compares initial rates only when the fixed threshold is small and consistent. |
To test the effect of one concentration, change only that starting concentration. Keep the total volume, the temperature and the other concentrations the same. A common way is to replace part of a solution with water. Measure the gradient at the start of each run, because concentrations fall as the reaction goes on. If a solid reacts, keep its particle size the same.
Worked examplePlan a rate measurement for calcium carbonate and acid
How could the effect of acid concentration be investigated using the carbon dioxide produced?
Try it first. Then show the worked stepsHide the worked steps
- Use a gas-tight flask connected to a gas syringe; use equal masses and a controlled size range of carbonate pieces.
- Use acid in excess and hold its total volume and temperature constant between runs.
- Start timing reproducibly at mixing and record gas volume at short intervals; use the initial tangent rather than the final gas volume.
- Repeat to assess scatter and check the apparatus for leaks.
Initial gas-volume gradients compare initial rates. The final volume mainly reflects the limiting amount, so it cannot by itself show which reaction was faster.
This is a sound way to plan an experiment on paper. The 9476 syllabus says you will not have to collect a gas with a gas syringe or by displacing water in the practical exam. You may still be asked to interpret gas-volume data or to describe a suitable method.
Watch out for this
A student says: "To compare initial rates, divide the total volume of gas collected by the time the reaction took." What is wrong with this?
Show the answer
That gives an average rate over the whole run, and the rate falls as the reactants are used up. Plot volume against time and take the gradient of the tangent at t = 0. A June 2021 Cambridge report says the popular wrong answer was gas volume divided by time taken, which does not give an initial rate.
Clock reactions time how long a small, fixed amount of product takes to form. Hans Heinrich Landolt first observed the iodine clock in 1886. Thiosulfate turns the first iodine back into iodide; once it runs out, iodine builds up and turns starch dark blue. The same idea works for other coloured products. A small, fixed amount of a substance removes the first product, so the colour appears only after a fixed amount has formed.
Check your understanding
Bromate, bromide and acid react at a measurable rate to make orange bromine. Even a trace of bromine shows, so the first colour appears almost at once in every run. How can a student time each run fairly?
Show the answer
Add a fixed small amount of phenol, then time the colour
Phenol removes the first bromine that forms. The orange colour appears only once that fixed amount of bromine has formed, so each time measures the same amount of reaction.
Check your understanding
Which method suits following the rate of a reaction in which purple MnO4- ions are used up?
Show the answer
Measure absorbance with a colorimeter at regular times
The colour fades as MnO4- is used up, so absorbance tracks its concentration. Calibrate absorbance against known concentrations.