Lesson 4 of 6
Measuring temperature
I can relate a temperature increase to greater average particle kinetic energy.Syllabus
Syllabus K323, 7(d). Relate a temperature increase to greater average particle kinetic energy.
Make a guess. You are not marked.
A thermometer has been lying on a bench in a room at 30 degrees C. You dip its bulb into iced water at 0 degrees C. What does it read one second later?
Show the answer
A value between 30 and 0 degrees C that is still falling.
The bulb must cool to the temperature of the water before it can show that temperature. This takes time, so wait until the reading stops changing.
A thermometer reads the temperature of its own sensing part. Place it so that part is at the temperature of the sample you want to measure.
Temperature relates to the average random kinetic energy of the particles. A reading is only useful if it belongs to the sample you mean.
Temperature may be represented by θ (theta) or T. The symbol θ commonly denotes a Celsius temperature in °C, while T commonly denotes a temperature in kelvin (K). These letters name the quantity; °C and K name the units. Always retain the stated scale and unit with a reading.
A thermometer measures temperature through a property that changes as its sensing region responds to the sample. Place and read it so that it represents the sample you intend to measure.
- Choose a suitable range and resolution. A thermometer covering -10°C to 110°C can include the 20°C and 50°C readings above. With divisions every 1°C, the scale does not justify reporting many decimal places.
- Immerse the sensing region correctly. Follow the instrument's immersion marking or instructions. A liquid-in-glass thermometer needs its bulb in the sample; do not leave the bulb mainly in the air above it.
- Avoid contact with the vessel. Keep the sensing region clear of the base and sides, especially while the vessel is being heated. Gentle stirring, where suitable, can reduce temperature differences within a liquid.
- Allow time for the response. For a sample held at a steady temperature, wait until the reading settles. If the sample is continuously warming, a slow thermometer can lag behind its changing temperature.
- Read the scale properly. View the top of a liquid-in-glass thermometer's column at eye level to reduce parallax. Record the unit and the relevant time when following a change.
Measurement reasoning
Two readings of the same warming liquid
A thermometer touches the heated base of a beaker. That region may be hotter than the bulk liquid, so its reading can be too high for the intended liquid temperature. Moving the sensor into the liquid, away from the base, addresses the placement problem.
A second thermometer is correctly placed but responds slowly. While the liquid warms, its reading can be below the liquid's current temperature. Repeating the same timing does not remove this response lag; use a suitable sensor and account for its response time.
Weather stations apply the same rule. Their thermometers sit inside a slatted box called a Stevenson screen, named after the engineer Thomas Stevenson. The box shields them from rain and direct radiation while air flows through. The World Meteorological Organization sets them 1.25 m to 2 m above the ground. The reading is then the temperature of the air, not of a sunlit instrument.
Repeating a reading does not fix a badly placed thermometer. Repeats show random variation. A bulb touching the heated base reads too high every time, so move the bulb.
Check your understanding
A student heats water in a beaker over a burner. She rests the thermometer bulb on the bottom of the beaker and takes three readings. Which of these describes her readings of the water temperature?
Show the answer
All too high, because the bulb touches glass that the flame heats.
The base of the beaker is hotter than most of the water. A bulb touching it reads the glass, not the water. Lift the bulb into the water, clear of the base and sides.