Lesson 1 of 6
Choose a measurement that answers the question
Apparatus choice depends on range, precision and what changes.
O-Level 5086 / 5088 (2026) / SEC G3 K326 / K328 (2027)
I can select measuring apparatus.Syllabus
Syllabus K326 / K328, 1.1(a). Select measuring apparatus
I can select simple experimental setups.Syllabus
Syllabus K326 / K328, 1.1(b). Select simple experimental setups
Choose a measurement that answers the question
Choose the apparatus by the quantity you measure and how precise the reading must be.
Make a guess. You are not marked.
You need to measure out 8 cm3 of water. Which gives the more precise reading: a 10 cm3 or a 100 cm3 measuring cylinder?
Show the answer
The 10 cm3 cylinder, as its scale marks are closer together
A small cylinder spreads a small volume up a tall scale, so each mark stands for less. Use the smallest cylinder that holds the volume.
Every measurement starts with two questions. Which quantity changes: time, temperature, mass or volume? And how precise must the reading be? A precise instrument has scale marks close together, so it can show small differences between readings.
| Quantity or task | Apparatus | Reason |
|---|---|---|
| Time | Stopwatch | Start and stop it at moments you decide in advance, such as when the acid is added. |
| Temperature | Thermometer or temperature probe | Put the bulb in the mixture itself, not against the hot wall of the container. |
| Mass | Balance | A typical school balance reads to 0.01 g. Zero it with the empty container on it, or subtract the mass of the container. |
| Rough volume of a liquid | Measuring cylinder | Quick, but the least precise. Use the smallest cylinder that holds the volume. |
| One fixed, accurate volume | Volumetric pipette and pipette filler | Delivers exactly the volume it is made for, such as 25.0 cm3. Fill it with the filler, never by mouth. |
| Any accurate volume up to 50 cm3 | Burette | Reads to the nearest 0.05 cm3. Volume delivered = final reading minus initial reading. |
| Volume of a gas | Gas syringe | Collects the gas and shows its volume on a scale. |
Read a liquid level with your eye level with it. Looking from above or below gives a wrong reading, called a parallax error. In a narrow tube, the surface of a liquid curves; this curve is the meniscus. For a clear solution, read the bottom of the meniscus.
In Singapore, the syllabus from SEAB, the national exam board, says to record burette readings to the nearest 0.05 cm3. So write every reading to two decimal places, such as 23.65 cm3. A burette filled to the zero mark reads 0.00 cm3, not 0.
A pipette and a burette are both precise, but they do different jobs. A pipette delivers one fixed volume. A burette delivers any volume up to 50 cm3, so it can measure a volume you do not know in advance. That is why a burette is used in a titration. In a titration, acid runs from the burette into a measured volume of alkali until an indicator just changes colour. The figures in a method also guide you: 25.0 cm3, with its .0, calls for a pipette, not a measuring cylinder.
The rate of a reaction is how fast reactants are used up or products are made. If a reaction gives off a gas, collect it in a gas syringe and read the volume every 30 seconds. Or stand the flask on a balance and record the mass as the gas escapes. A loose plug of cotton wool lets the gas out but keeps acid spray in. The balance suits a heavy gas such as carbon dioxide. Hydrogen is so light that the mass hardly changes, so use a gas syringe for it.
Worked exampleMeasure a rate rather than an endpoint
Compare how fast magnesium reacts with hydrochloric acid of two different concentrations.
Try it first. Then show the worked stepsHide the worked steps
- Keep everything else the same: the mass and surface area of the magnesium, the volume of acid and the starting temperature.
- Collect the hydrogen in a gas syringe joined by an airtight tube. Start the stopwatch as the magnesium meets the acid, and record the volume every 30 s.
- Plot volume against time for each concentration. Compare the gradients at the start, or the times taken to collect the same volume. Repeat to check that the results agree.
The steeper volume-time graph shows the faster reaction. The final volume alone cannot show the rate: if all the magnesium reacts both times, both reactions end with the same volume of hydrogen.
Check your understanding
A burette reads 1.20 cm3 at the start and 23.65 cm3 at the end. What volume was delivered?
Show the answer
22.45 cm3, the final reading minus the initial reading
23.65 - 1.20 = 22.45 cm3. The final reading is the delivered volume only if the burette started at 0.00 cm3.
Check your understanding
In a titration, acid is added to 25.0 cm3 of alkali until the indicator just changes colour. Which apparatus should add the acid?
Show the answer
A burette, as it measures whatever volume turns out to be needed
The volume of acid needed is not known until the colour changes. A burette adds acid drop by drop and reads any volume to the nearest 0.05 cm3.
Watch out for this
A student says: "A burette is used to add the acid because a burette is accurate." What is wrong with this?
Show the answer
This compares nothing, so it does not score. Say what it is more accurate than. A burette measures volume more accurately than a measuring cylinder, because it reads to the nearest 0.05 cm3. Examiners report that "a burette is accurate" on its own is not enough unless it is compared with the measuring cylinder.